Tools Required
J 39400-A
Halogen Leak Detector
Removal Procedure
- Recover the refrigerant from the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Remove the evaporator tube to thermostatic expansion valve (TXV) nut (1).
- Disconnect the evaporator outlet and inlet tube from the TXV.
- Remove and discard the sealing washers.
Important: Cap or tape the open evaporator inlet and outlet tubes immediately to prevent contamination of the refrigerant system.
- Cap off the evaporator inlet and outlet tube.
- Remove the TXV to evaporator bolts.
- Remove the TXV from the evaporator core.
- Remove and discard the sealing washers.
Installation Procedure
- Install the new sealing washers onto the evaporator core. Refer to
Sealing Washer Replacement
.
- Install the TXV to the evaporator core.
Notice: Refer to Fastener Notice in the Preface section.
- Install the TXV to evaporator bolts.
Tighten
Tighten the bolts to 7 N·m (62 lb in).
- Remove the cap or tape from the evaporator inlet and outlet tubes.
- Install the new sealing washers onto the evaporator inlet and outlet tubes. Refer to
Sealing Washer Replacement
.
- Install the evaporator outlet and inlet tube to the TXV.
- Install the evaporator tube nut (1).
Tighten
Tighten the nut to 17 N·m (12.5 lb ft).
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the component using
J 39400-A
.