• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provide an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
TFT Sensor Signal | P0712 | P0713 | P0713 | P0218, P0711 |
Low Reference | -- | P0713 | -- | P0218, P0711 |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage |
---|---|---|---|
Operating Conditions: Engine running in PARK, normal operating temperature Parameter Normal Range: -40 to +149°C (-40 to +300°F) | |||
Trans. Fluid Temp. | Greater than 149°C (300°F) | Less than -40°C (-40°F) | Less than -40°C (-40°F) |
The automatic TFT sensor is a thermistor. The TFT sensor is part of the automatic transmission fluid pressure (TFP) manual valve position switch. The transmission control module (TCM) supplies a 5-volt reference signal to the sensor. When the transmission fluid is cold, the sensor resistance is high and the TCM senses a high signal voltage. As the transmission fluid warms, the sensor resistance lowers and the TCM senses lower voltage. The TCM uses the TFT reading in order to control the torque converter clutch (TCC), line pressure adjustments, and temperature compensated shifts.
The engine is running for 5 seconds.
• | No ISS DTC P0716 or P0717. |
• | No OSS DTC P0722 or P0723. |
• | The engine is running for 5 seconds. |
• | The output speed is 70 RPM or greater for 200 seconds cumulatively. |
• | The TCC slip speed is 120 RPM or greater for 200 seconds cumulatively. |
The TFT sensor is greater than 150°C (302°F) for 12 seconds.
The TFT is less than -40°C (-40°F) for 1 minute and 20 seconds.
• | DTC P0712 and P0713 are type C DTCs. |
• | The TCM freezes transmission adaptive functions. |
• | The TCM calculates a default TFT based on engine coolant temperature (ECT), intake manifold air temperature, and engine run time. |
DTC P0712 and P0713 are type C DTCs.
Automatic Transmission Controls Schematics
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
• | J 35616 GM Terminal Test Kit |
• | J 44152 Jumper Harness (20 pins) |
Start the engine. With the vehicle in PARK and at normal operating temperature, observe the Trans. Fluid Temp. parameter on the scan tool. The Trans. Fluid Temp. should display near the ECT sensor parameter.
Important: If a short to voltage is found, test the TFT sensor for damage.
⇒ | If the voltage is less than the specified range, test the TFT sensor signal circuit for an open, high resistance or short to ground. If the voltage is greater than the specified range, test the TFT sensor signal circuit for a short to voltage. |
⇒ | If the voltage is less than the specified value, test the low reference circuit for an open, high resistance, or short to ground. |
⇒ | If the resistance is greater than the specified range for a given temperature, test the TFT sensor signal circuit and the low reference circuit for an open or high resistance. If the resistance is less than the specified range, test the TFT sensor signal circuit and the low reference for a shorted together condition or a faulty TFT sensor. If a shorted together condition is found, replace the transmission wiring harness. |
⇒ | If the resistance is less than 10K ohms, test the TFT sensor signal circuit for a short to the transmission case. If a short to the case is found, replace the transmission wiring harness. |
⇒ | If the resistance is less than 10K ohms, test the low reference circuit for a short to the transmission case. If a short to the case is found, replace the transmission wiring harness. |
⇒ | If the resistance is less than 10K ohms, replace the transmission wiring harness. |
Install the J 44152 jumper harness (20 pins) on the transmission side of the automatic transmission 20-way inline connector. Using the J 35616 GM terminal test kit, measure the resistance between the TFT sensor signal circuit and the low reference circuit. Refer to Transmission Fluid Temperature Sensor Specifications .
⇒ | If the resistance is not within the specified range, replace the transmission wiring harness or the TFT sensor. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for TCM replacement, setup, and programming