• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage | Signal Performance |
---|---|---|---|---|---|
Engine Oil Pressure 5-Volt Reference | P0522 | 1 | P0522 | P0523 | P0521 |
Engine Oil Pressure Sensor Signal | P0522 | 1 | P0522 | P0523 | P0521 |
Low Reference | -- | 1 | P0523 | -- | P0521 |
1. Engine Oil Pressure Indicator Malfunction |
The engine oil pressure (EOP) sensor changes voltage based on the engine oil pressure. The EOP sensor is a 3-wire sensor comprising of the signal circuit, the low reference circuit and the 5-volt reference circuit. The engine control module (ECM) supplies 5 volts to the EOP sensor via the 5-volt reference circuit and provides ground via the EOP low reference circuit. The ECM monitors the signal circuit of the EOP sensor to determine if the engine oil pressure sensor voltage is within the normal operating range of approximately 1-4 volts. When the engine oil pressure is high, the EOP sensor voltage is high and the ECM senses a high signal voltage. When the engine oil pressure is low, the EOP sensor voltage is low and the ECM senses a low signal voltage. The ECM sends the EOP information to the instrument panel cluster (IPC) via the serial data circuit.
• | The engine is idling at less than 640 RPM and the engine oil pressure sensor performance check is high. |
• | The engine is running at greater than 1520 RPM and the engine oil pressure sensor performance check is low. |
• | The engine oil pressure is greater than 880 kPa (127.6 psi). |
• | The engine oil pressure is less than 8 kPa (1.16 psi). |
• | The ECM detects that the EOP sensor signal circuit is less than 0.195 volt. |
• | The above condition is present for greater than 10 seconds. |
• | The ECM detects that the EOP sensor signal circuit is greater than 4.8 volts. |
• | The above condition is present for greater than 10 seconds. |
• | The ECM records the operating conditions at the time the diagnostics test fails. The ECM displays this information in the Failure Records on the scan tool. |
• | The IPC illuminates the EOP indicator. |
• | The DTC becomes history when the conditions for setting the DTC are no longer present. |
• | The history DTC clears after 40 malfunction-free warm-up cycles. |
Control Module References for scan tool information
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the signal circuit terminal 3 for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Engine Oil Pressure Sensor and/or Switch Replacement for the 2.8L, 3.0L, 3.2L, and 3.6L engines |
• | Engine Oil Pressure Sensor and/or Switch Replacement for the 4.8L, 5.3L, 6.0L, 6.2L and 7.0L engines |