Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Using a DMM, measure the voltage between the generator terminal L and ground. Is the voltage greater than the specified value? | 8 Volts | ||
2 | Using a DMM, measure the voltage from the BATT terminal (RED) and ground. Is the voltage greater than the specified value? | 8 Volts | ||
3 |
All accessories turned OFF. Using a DMM, measure the voltage across the battery terminals. Is the voltage between the specified values? | 13.3 and 15.5 Volts | ||
4 |
If generator is OK, perform a battery load test. Is repair completed? | -- | -- | |
5 | Check for open or poor connections in CKT 225, (RED), between the generator terminal L and the PCM connector C2, terminal 35. Is repair completed? | -- | -- | |
6 | Check for an open in CKT 1 between the generator BATT terminal and the battery. Is the repair completed? | -- | -- | |
7 | Repair or replace the generator. Is the repair completed? | -- | -- |