Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |
2 |
Does the VOLTS indicator light? | -- | Go to Step 4 | Go to Step 3 |
3 | Inspect CKT 25 (BRN) for an open or high resistance. Is the resistance within the specified range? | ∞ | Go to Step 7 | Go to Step 5 |
4 | Inspect the PCM connector C2 for proper contact. Was a poor connection found? | -- | Go to Step 8 | |
5 | Inspect connector C200 cavity C4 for proper terminal contact. Was a poor connection found? | -- | Go to Step 9 | Go to Step 6 |
6 | Replace the instrument cluster. Is the repair complete? | -- | -- | |
7 | Repair the open in CKT 25 (BRN). Refer to Repairing Damaged Wire Insulation in Wiring Systems. Is the repair complete? | -- | -- | |
8 | Repair the PCM connector C2. Refer to Terminal Repair in Wiring Systems. Is the repair complete? | -- | -- | |
9 | Repair connector C200 cavity C4. Refer to Terminal Repair in Wiring Systems. Is the repair complete? | -- | -- |