Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Did you perform the Audible Warnings System Check? | -- | Go to Step 2 | |||||
2 |
Does the resistance measure less than the specified value? | 10 ohms | Go to Step 4 | Go to Step 3 | ||||
3 | Replace the fasten seat belts indicator. Refer to Instrument Cluster Warning Lamp Replacement in Instrument Panel, Gauges, and Console. Is the replacement complete? | -- | -- | |||||
4 |
Does the measured voltage equal the specified value for approximately 1 minute after you turn the ignition switch to the RUN position? | 10-15 V | Go to Step 9 | Go to Step 5 | ||||
5 | Inspect CKT 234 (YEL) for an open or short to ground. Is the circuit OK? | -- | Go to Step 7 | Go to Step 6 | ||||
6 | Repair the open or short to ground in CKT 234 (YEL). Refer to Repairing Damaged Wire Insulation in Wiring Systems. Is the repair complete? | -- | Go to Step 7 | -- | ||||
7 | For U23 only, inspect connector C200 terminal D12 for proper terminal contact. Is the contact OK? | -- | Go to Step 8 | Go to Step 12 | ||||
8 | Replace the MALL module. Refer to Multifunction Alarm, Lock and Lighting Module Replacement in Instrument Panel, Gauges and Console. Is the replacement complete? | -- | -- | |||||
9 | Inspect CKT 1250 (BLK) for an open. Is the circuit OK? | -- | Go to Step 11 | Go to Step 10 | ||||
10 | Repair the open in CKT 1250 (BLK). Refer to Repairing Damaged Wire Insulation in Wiring Systems. Is the repair complete? | -- | -- | |||||
11 |
Are the contacts OK? | -- | Go to Step 12 | |||||
12 | Repair the poor terminal contact. Refer to Terminal Repairs in Wiring Systems. Is the repair complete? | -- | -- |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Audible Warnings System Check? | -- | Go to Step 2 | |
2 |
Does the resistance measure less than the specified value? | 10 ohms | Go to Step 4 | Go to Step 3 |
3 | Replace the fasten seat belts indicator. Refer to Instrument Cluster Indicator Warning Lamp Replacement in Instrument Panel, Gauges and Console. Is the replacement complete? | -- | -- | |
4 |
Does the measured voltage equal the specified value for approximately 1 minute after you turn the ignition switch to the RUN position? | 10-15 V | Go to Step 9 | Go to Step 5 |
5 | Inspect CKT 234 (YEL) for an open or short to ground. Is the circuit OK? | -- | Go to Step 7 | Go to Step 6 |
6 | Repair the open or short to ground in CKT 234 (YEL). Refer to Repairing Damaged Wire Insulation in Wiring Systems. Is the repair complete? | -- | -- | |
7 | Inspect the MALL module connector C2 terminal D12 for proper terminal contact. Is the contact OK? | -- | Go to Step 8 | Go to Step 12 |
8 | Replace the MALL module. Refer to Multifunction Alarm, Lock and Lighting Module Replacement in Instrument Panel, Gauges and Console. Is the replacement complete? | -- | -- | |
9 | Inspect CKT 1250 (BLK) for an open. Is the circuit OK? | -- | Go to Step 11 | Go to Step 10 |
10 | Repair the open in CKT 1250 (BLK). Refer to Repairing Damaged Wire Insulation in Wiring Systems. Is the repair complete? | -- | -- | |
11 | Inspect the instrument cluster connector C2 terminal E13 for proper terminal contact. Are the contacts OK? | -- | Go to Step 12 | |
12 | Repair the poor terminal contact. Refer to Terminal Repairs in Wiring Systems. Is the repair complete? | -- | -- |
Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Audible Warnings System Check? | -- | Go to Step 2 | |||||||
2 |
Does the resistance measure less than the specified value? | 10 ohms | Go to Step 4 | Go to Step 3 | ||||||
3 | Replace the fasten seat belts indicator. Refer to Instrument Cluster Indicator Warning Lamp Replacement in Instrument Panel, Gauges, and Console. Is the replacement complete? | -- | -- | |||||||
4 |
Does the measured voltage equal the specified value for approximately 1 minute after you turn the ignition switch to the RUN position? | 10-15 V | Go to Step 9 | Go to Step 5 | ||||||
5 | Inspect CKT 234 (YEL) for an open or short to ground. Is the circuit OK? | -- | Go to Step 7 | Go to Step 6 | ||||||
6 | Repair the open or the short to ground in CKT 234 (YEL). Refer to Repairing Damaged Wire Insulation in Wiring Systems. Is the repair complete? | -- | -- | |||||||
7 | Inspect connector C200 terminal D12 for proper terminal contact. Is the contact OK? | -- | Go to Step 8 | Go to Step 12 | ||||||
8 | Replace the MALL module. Refer to Multifunction Alarm, Lock and Lighting Module Replacement in Instrument Panel, Gauges, and Console. Is the replacement complete? | -- | -- | |||||||
9 | Inspect CKT 1250 (BLK) for an open. Is the circuit OK? | -- | Go to Step 11 | Go to Step 10 | ||||||
10 | Repair the open in CKT 1250 (BLK). Refer to Repairing Damaged Wire Insulation in Wiring Systems. Is the repair complete? | -- | -- | |||||||
11 |
Are the contacts OK? | -- | Go to Step 12 | |||||||
12 | Repair the poor terminal contacts. Refer to Terminal Repairs in Wiring Systems. Is the repair complete? | -- | -- |