Step | Action | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the System Performance Test? | Go to Step 2 | Go to System Performance Test | ||||||||
2 | Are the high and low pressures above normal according to the performance chart readings? | Go to Step 11 | Go to Step 3 | ||||||||
3 | When performing the system performance test, compared to the performance chart, inspect for the following:
Do the listed conditions exist? | Go to Step 4 | Go to Step 5 | ||||||||
4 |
Did you complete the repair(s)? | Go to Step 18 | -- | ||||||||
5 | When performing the system performance test, did the high and low side pressures remain equal and not change while the compressor was running? | Go to Step 7 | Go to Step 6 | ||||||||
6 | When performing the system performance test, compared to the performance chart, inspect for the following:
Do the listed conditions exist? | Go to Step 8 | Go to Step 9 | ||||||||
7 |
Did you find and correct the condition? | Go to Step 18 | Go to Step 8 | ||||||||
8 | Replace the A/C compressor. Refer to Air Conditioning Compressor Replacement . Did you complete the repair? | Go to Step 18 | -- | ||||||||
9 | When performing the system performance test, did the compressor clutch cycle ON/OFF rapidly and cause compressor noise? | Go to Step 10 | Go to Step 12 | ||||||||
10 |
Did you find and correct the condition? | Go to Step 18 | -- | ||||||||
11 | Inspect for improperly working cooling fans. Are the cooling fans operating properly? | Go to Step 12 | Go to Electric Cooling Fan Diagnosis in Engine Controls | ||||||||
12 | When performing the system performance test, was the liquid line warm downstream of the orifice tube? | Go to Step 13 | Go to Step 14 | ||||||||
13 |
Did you complete the repair(s)? | Go to Step 18 | -- | ||||||||
14 | When performing the system performance test, was the liquid line cold upstream of the orifice tube? | Go to Step 15 | Go to Step 16 | ||||||||
15 | Locate the restriction in the high side line and repair. Did you complete the repair? | Go to Step 18 | -- | ||||||||
16 | Inspect the A/C condenser for blockages, bent or damaged fins causing insufficient air flow. Did you find and correct the condition? | Go to Step 18 | Go to Step 17 | ||||||||
17 |
Did you complete the repair? | Go to Step 18 | -- | ||||||||
18 | Operate the system in order to verify the repair. Did you correct the condition? | System OK |