CCP -- HVAC System Data -- Temp. Dr. Commanded: The scan tool displays 0 to 100%. The position of the temperature
door in terms of a percentage of total travel.
CCP -- HVAC System Data -- HTR/DEF/AC Dr Commanded: The scan tool displays 0 to 100%. The position of the HTR/DEF/AC
door in terms of a percentage of total travel.
CCP -- HVAC System Data -- Air Inlet Dr Commanded: The scan tool displays 0 to 100%. The position of the air inlet
door in terms of a percentage of total travel.
CCP -- HVAC System Data -- Commanded Blower: The scan tool displays 0 to 100%. The speed of the blower motor
in terms of a percentage of max speed.
CCP -- Special Functions -- Temp. Door Position: The scan tool displays Hot or Cold selections. The selection drives
the door to its min or max positions.
CCP -- Special Functions -- HTR/DEF/AC Door Position: The scan tool displays Defrost or A/C selections. The selection
drives the door to its min or max positions.
CCP -- Special Functions -- Air Inlet Door Position: The scan tool displays Outside or Recirc selections. The selection
drives the door to its min or max positions.
CCP -- Miscellaneous Tests -- Blower Motor: The scan tool displays Off or On selections. The selection drives
the blower motor to its min and max speeds.
DIM -- A/C Information -- A/C Clutch (Actual): The scan tool displays On or Off. On is displayed when the PCM
has energized the A/C clutch relay.
DIM -- A/C Information -- A/C Clutch (Desired): The scan tool displays On or Off. On is displayed when the heater
and A/C control is requesting A/C system operation and the DIM has determined
that none of the system performance limits are exceeded.
DIM -- A/C Information -- Control Head (Desired): The scan tool displays A/C On or A/C Off. A/C On is displayed when
the heater and A/C control is requesting A/C system operation.
DIM -- A/C Information -- A/C Pressure: The scan tool displays 0 to 4000 kPa (0 to 580 psi). The output
of the A/C pressure sensor provided by the PCM over the Class 2 communication
link.
DIM -- A/C Information -- Pressure Status: The scan tool displays Low, Normal or High. Normal must be displayed
to allow A/C operation.
DIM -- A/C Information -- Temperature Status: The scan tool displays Hot or OK. Hot is displayed when engine
coolant temperature rises above 121°C (250°F). OK must be displayed
to allow A/C operation.
DIM -- A/C Information -- Clutch Voltage.: The scan tool displays Low or Normal. Low is displayed when the
battery voltage is low, such that clutch slippage is possible.
PCM -- Engine Data 1 -- ECT: The scan tool displays -40 to 215°C (-40 to 420°F). The
output of the engine coolant temperature sensor.
PCM -- Engine Data 2 -- ECT: The scan tool displays -40 to 215°C (-40 to 420°F). The
output of the engine coolant temperature sensor.
PCM -- Engine Data 2 -- Commanded A/C: The scan tool displays On or Off. On is displayed when the PCM
has energized the A/C clutch relay.
PCM -- Engine Data 2 -- A/C High Side Pressure: The scan tool displays 0 to 5 volts. The output of the A/C pressure
sensor.
PCM -- Engine Data 2 -- A/C Pressure Out Of Range: The scan tool displays Yes or No. Yes is displayed when the system
pressure exceeds 2968 kPa (430 psi).
PCM -- Output Driver Data -- A/C Relay: The scan tool displays OK or Fault. Fault is displayed when an
open or short is detected in the A/C CLU relay ground circuit.
PCM -- Engine Output Controls -- A/C Relay: The scan tool displays Off or On selections. This command allows
you to turn the A/C relay OFF and ON.