Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check |
2 |
IMPORTANT: Outside air temperature must be above 16°C (60°F).
Does the A/C compressor operate? | -- | Go to Step 3 | |
3 | Does the blower operate and provide sufficient airflow? | -- | Go to Step 4 | |
4 | Use the heater and A/C control to adjust the temperature from COOL to WARM. Does the air mix actuator rotate with each command? | -- | Go to Step 5 | Go to Step 6 |
5 | Perform the refrigerant system performance test. Refer to System Performance Test . Are low and high side pressures within specification? | -- | System OK | |
6 |
Does the air mix actuator rotate with each command? | -- | Go to Step 15 | Go to Step 7 |
7 |
Does the voltage measure near the specified value? | 12V | Go to Step 8 | Go to Step 10 |
8 | Measure the voltage from the supply circuit of the air mix actuator to the motor return circuit of the air mix actuator. Does the voltage measure near the specified value? | 12V | Go to Step 9 | Go to Step 11 |
9 |
Does the voltage change? | -- | Go to Step 13 | Go to Step 12 |
10 |
Did you find and correct the condition? | -- | Go to Step 18 | -- |
11 |
Did you find and correct the condition? | -- | Go to Step 18 | -- |
12 |
Did you find and correct the condition? | -- | Go to Step 18 | -- |
13 |
Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 14 |
14 | Inspect the air mix actuator and air mix doors for binding or mechanical failure. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 16 |
15 | Inspect for poor connections at the harness connector of the heater and A/C control. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 17 |
16 | Replace the air mix actuator. Refer to Temperature Actuator Replacement . Did you complete the replacement? | -- | Go to Step 18 | -- |
17 | Replace the heater and A/C control. Refer to Control Assembly Replacement . Did you complete the replacement? | -- | Go to Step 18 | -- |
18 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |