Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check |
2 |
Does the air flow change discharge locations? | Go to Step 3 | Go to Step 4 |
3 | With a scan tool, command the HTR/DEF/AC door position from Defrost to Panel. Does the air flow change discharge locations? | Go to Step 5 | Go to Step 4 |
4 |
Does the scan tool display any DTCs. | Go to DTC Table | Go to Step 6 |
5 |
Does the paper stay in place? | Go to Step 8 | Go to Step 12 |
6 | Inspect the mode actuator for binding or mechanical failure. Did you find and correct the condition? | Go to Step 18 | Go to Step 7 |
7 | Inspect for blocked or misaligned ducts. Did you find and correct the condition? | Go to Step 18 | Go to Step 13 |
8 | Inspect for poor connections at the harness connector of the inside air temp sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 9 |
9 | Test the inside air temp sensor resistance. Refer to Sensor Resistance Table . Is the resistance within the specified values? | Go to Step 10 | Go to Step 15 |
10 | Inspect for poor connections at the harness connector of the outside air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 11 |
11 | Test the outside air temperature sensor resistance. Refer to Sensor Resistance Table . Is the resistance within the specified values? | Go to Step 17 | Go to Step 16 |
12 | Inspect for blockage, disconnected or poor fitting foam seals at the sensor air inlet. Did you find and correct the condition? | Go to Step 18 | -- |
13 | Inspect for poor connections at the harness connector of the mode actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 14 |
14 | Replace the mode actuator. Refer to Mode Actuator Replacement . Did you complete the replacement? | Go to Step 18 | -- |
15 | Replace the inside air temp sensor. Refer to Inside Air Temperature Sensor Replacement . Did you complete the replacement? | Go to Step 18 | -- |
16 | Replace the outside air temperature sensor. Refer to Ambient Temperature Sensor Replacement . Did you complete the replacement? | Go to Step 18 | -- |
17 |
Does the system operate correctly? | System OK | Go to Symptoms |
18 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |