IPM -- HVAC Sensors -- Outside Air Temp: The scan tool displays -40 to 60°C (-40 to 140°F).
The output of the ambient air temperature sensor.
IPM -- HVAC Sensors -- Inside Air Temp: The scan tool displays -40 to 60°C (-40 to 140°F).
The output of the inside air temperature sensor.
IPM -- HVAC Sensors -- Left AC Duct Temp: The scan tool displays -40 to 150°C (-40 to 300°F).
The output of the LH A/C duct temperature sensor.
IPM -- HVAC Sensors -- Left HTR Duct Temp: The scan tool displays -40 to 150°C (-40 to 300°F).
The output of the LH HTR duct temperature sensor.
IPM -- HVAC Sensors -- Right AC Duct Temp: The scan tool displays -40 to 150°C (-40 to 300°F).
The output of the RH A/C duct temperature sensor.
IPM -- HVAC Sensors -- Right HTR Duct Temp: The scan tool displays -40 to 150°C (-40 to 300°F).
The output of the RH HTR duct temperature sensor.
IPM -- HVAC Sensors -- Left Duct Temp Desired: The scan tool displays -18 to 120°C (0 to 250°F).
The target LH A/C duct temperature that the HVAC system is trying to achieve.
IPM -- HVAC Sensors -- Right Duct Temp Desired: The scan tool displays -18 to 120°C (0 to 250°F).
The target RH A/C duct temperature that the HVAC system is trying to achieve.
IPM -- HVAC Sensors -- Left Solar: The scan tool displays 0 to 50 counts. The solar load output
of the LH sunload sensor and ambient light sensor.
IPM -- HVAC Sensor -- Right Solar: The scan tool displays 0 to 50 counts. The solar load output
of the RH sunload sensor and ambient light sensor.
IPM -- HVAC System Data -- System Program Number: The scan tool displays 0 to 255 counts. The operating point
of the climate control system based on sensor inputs and driven by a combination
of both driver and passenger set temperatures.
IPM -- HVAC System Data -- Left Program Number: The scan tool displays 0 to 255 counts. The operating point
of the climate control system based on sensor inputs and driven by the driver
set temperature.
IPM -- HVAC System Data -- Right Program Number: The scan tool displays 0 to 255 counts. The operating point
of the climate control system based on sensor inputs and driven by the passenger
set temperature.
IPM -- HVAC System Data -- Commanded Blower: The scan tool displays 0 to 100%.
IPM -- HVAC System Data -- Selected Air Mode: The scan tool displays AUTO, Upper, Defog, Bi-Level, Heater or
Defrost. The current operating mode of the HVAC system.
IPM -- HVAC System Data -- A/C Requested: The scan tool displays Yes or No. The message sent out on class
2 to the DIM when A/C is requested.
IPM -- HVAC System Data -- Coolant Temperature: The scan tool displays -40 to 120°C (-40 to 250°F).
The information is received from the PCM on the class 2 communication link.
IPM -- HVAC Door Positions -- Left Temp. Dr. Commanded: The scan tool displays 0 to 255 counts (0 to 5 volts).
The desired position of the actuator.
IPM -- HVAC Door Positions -- Left Temp Dr Actual: The scan tool displays 0 to 255 counts (0 to 5 volts).
The signal output from the feedback pot on the actuator.
IPM -- HVAC Door Positions -- Right Temp. Dr. Commanded: The scan tool displays 0 to 255 counts (0 to 5 volts).
The desired position of the actuator.
IPM -- HVAC Door Positions -- Right Temp Dr Actual: The scan tool displays 0 to 255 counts (0 to 5 volts).
The signal output from the feedback pot on the actuator.
IPM -- HVAC Door Positions -- HTR/DEF/AC Dr Commanded: The scan tool displays 0 to 255 counts (0 to 5 volts).
The desired position of the actuator.
IPM -- HVAC Door Positions -- HTR/DEF/AC Dr Actual: The scan tool displays 0 to 255 counts (0 to 5 volts).
The signal output from the feedback pot on the actuator.
IPM -- HVAC Door Positions -- Air Inlet Dr Commanded: The scan tool displays 0 to 255 counts (0 to 5 volts).
The desired position of the actuator.
IPM -- HVAC Door Positions -- Air Inlet Dr Actual: The scan tool displays 0 to 255 counts (0 to 5 volts).
The signal output from the feedback pot on the actuator.
IPM -- HVAC Door Calibrations -- Min Left Temp Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The minimum travel range when driven to the stop during Recalibrate All Motors
command.
IPM -- HVAC Door Calibrations -- Max Left Temp Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The maximum travel range when driven to the stop during Recalibrate All Motors
command.
IPM -- HVAC Door Calibrations -- Min Right Temp Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The minimum travel range when driven to the stop during Recalibrate All Motors
command.
IPM -- HVAC Door Calibrations -- Max Right Temp Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The maximum travel range when driven to the stop during Recalibrate All Motors
command.
IPM -- HVAC Door Calibrations -- Min HTR/DEF/AC Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The minimum travel range when driven to the stop during Recalibrate All Motors
command.
IPM -- HVAC Door Calibrations -- Max HTR/DEF/AC Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The maximum travel range when driven to the stop during Recalibrate All Motors
command.
IPM -- HVAC Door Calibrations -- Min Air Inlet Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The minimum travel range when driven to the stop during Recalibrate All Motors
command.
IPM -- HVAC Door Calibrations -- Max Air Inlet Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The maximum travel range when driven to the stop during Recalibrate All Motors
command.
IPM -- Open/Short Data -- Outside Air Temp: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- Open/Short Data -- Inside Air Temp: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- Open/Short Data -- Left AC Duct Temp: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- Open/Short Data -- Left HTR Duct Temp: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- Open/Short Data -- Right AC Duct Temp: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- Open/Short Data -- Right HTR Duct Temp: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- Open/Short Data -- Left Solar Sensor: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- Open/Short Data -- Right Solar Sensor: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- HVAC Motors-- Left Temp Door Position: The scan tool displays Hot or Cold selections. The selection drives
the actuator to its min or max stop.
IPM -- HVAC Motors -- Right Temp Door Position: The scan tool displays Hot or Cold selections. The selection drives
the actuator to its min or max stop.
IPM -- HVAC Motors -- HTR/DEF/AC Door Position: The scan tool displays Defrost or Panel selections. The selection
drives the actuator to its min or max stop.
IPM -- HVAC Motors -- Air Inlet Door Position: The scan tool displays Outside or Recirc. selections. The selection
drives the actuator to its min or max stop.
IPM -- Miscellaneous Tests -- Instant OAT Update: The scan tool displays Commanded State: None or On. Updates the
IPM outside air temperature input to the current raw value.
IPM -- Miscellaneous Tests -- Blower Motor: The scan tool displays Commanded State: None, Off or On. This function
allows you to command the blower motor to its maximum (100%) or minimum (0%)
speeds.
IPM -- Miscellaneous Tests -- Recalibrate All Motors: The scan tool displays Commanded State: None or On. This function
commands the actuators to drive to the stops fully opened and fully closed
and relearn these endpoints.
IPM -- Miscellaneous Tests -- Relearn Control Panel Type: The scan tool displays Commanded State: None or On. This function
has the IPM relearn a new climate control panel.
IPM -- Set Options -- Afterblow: Allows the blower motor to run after the ignition is turned OFF.
IPM -- Temperature Offset: Allows for variation between driver set temperature and target
(desired) system discharge temperature.
DIM -- A/C Information -- A/C Clutch (Actual): The scan tool displays On or Off. On is displayed when the PCM
has energized the A/C clutch relay.
DIM -- A/C Information -- A/C Clutch (Desired): The scan tool displays On or Off. On is displayed when the IPM
is requesting A/C system operation and the DIM has determined that none of
the system performance limits are exceeded.
DIM -- A/C Information -- Control Head (Desired): The scan tool displays A/C On or A/C Off. A/C On is displayed when
the IPM is requesting A/C system operation.
DIM -- A/C Information -- A/C Pressure: The scan tool displays 0 to 4000 kPa (0 to 580 psi).
The output of the A/C pressure sensor provided by the PCM over the Class 2
communication link.
DIM -- A/C Information -- Pressure Status: The scan tool displays Low, Normal or High. Normal must be displayed
to allow A/C operation.
DIM -- A/C Information -- Temperature Status: The scan tool displays Hot or OK. Hot is displayed when engine
coolant temperature rises above 121°C (250°F). OK must be displayed
to allow A/C operation.
DIM -- A/C Information -- Clutch Voltage.: The scan tool displays Low or Normal. Low is displayed when the
battery voltage is low, such that clutch slippage is possible.
PCM -- Engine Data 1 -- ECT: The scan tool displays -40 to 215°C (-40 to 420°F).
The output of the engine coolant temperature sensor.
PCM -- Engine Data 2 -- ECT: The scan tool displays -40 to 215°C (-40 to 420°F).
The output of the engine coolant temperature sensor.
PCM -- Engine Data 2 -- Commanded A/C: The scan tool displays On or Off. On is displayed when the PCM
has energized the A/C clutch relay.
PCM -- Engine Data 2 -- A/C High Side Pressure: The scan tool displays 0 to 5 volts. The output of the A/C
pressure sensor.
PCM -- Engine Data 2 -- A/C Press. Out Of Range: The scan tool displays Yes or No. Yes is displayed when the system
pressure exceeds 2968 kPa (430 psi).
PCM -- Output Driver Data -- A/C Relay: The scan tool displays OK or Fault. Fault is displayed when an
open or short is detected in the A/C CLU relay ground circuit.
PCM -- Engine Output Controls -- A/C Relay: The scan tool displays Off or On selections. This command allows
you to turn the A/C relay OFF and ON.
DDM -- Data Display -- Pass. HVAC Switch: The scan tool displays 0 to 255 counts. This indicates which
passenger climate control button is being pressed.