The afterblow mode can be enabled using the scan tool.
The afterblow mode allows the blower motor to operate after the engine has
been turned off. This operation of the blower motor dries the evaporator
core which reduces the amount of microbial growth which can create undesirable
odors.
When the afterblow mode has been enabled the blower motor will operate
at medium speed for 4 minutes after the engine has been turned off. The following
conditions must be met for the IPM to operate the afterblow:
• | The outside air temperature is at least 21°C (70°F). |
• | The A/C compressor was operating for longer than 3 minutes. |
• | The engine has been turned off for at least 45 minutes. |
• | The system voltage is at least 12 volts. |
Afterblow Mode Enabling Procedure
The Scan Tool
will
recalibrate the IPM to enable the afterblow mode.
- Connect the Scan Tool
.
- The ignition should be ON, but the engine should not be operating.
- Select Instrument Panel Module.
- Select Special Functions.
- Select Set Options.
- Select Afterblow.