Dash Integration Module (DIM)
Important: The air bag indicator light may remain ON after the DIM module is replaced,
and during the programming procedure for the DIM, until after the procedure
is completed and the ignition key is cycled OFF and ON .
• | Before replacement, record the personalization settings to transfer
to the new module (if they are available). |
• | After replacement of the DIM, perform the following procedure. |
• | In order to reprogram the DIM, perform the following procedure. |
- Using a scan tool, preform the New VIN Procedure.
- Perform the Setup SDM Serial Number in DIM Procedure.
- Using the scan tool, set the Point of Sale in the DIM module to
the correct country.
- Using the scan tool, configure the RPO option configuration.
- Perform the vehicle personalization in order to reset the owner's
desired personalization settings. Refer to Instrument Cluster, Gauges and
Console.
Procedure to Set Up A New DIM Module
- Connect a scan tool to the data link connector (DLC).
- Turn ON the ignition, with the engine OFF.
- Under the DIM Main Menu, select Special Functions. Under the Special
Functions menu, one of the choices is New VIN.
- The user selects one of the following options:
• | New VIN, (to continue with the procedure) |
• | Exit, in order to go back to Special Functions menu |
- After the user chooses New VIN, follow the scan tool on screen
instructions in order to edit the VIN:
• | Press Save, in order to save the VIN information. |
• | Press Done, in order to go back to the Special Functions menu. |
- Under the Special Functions menu, one of the choices is Setup
SDM Serial Number in DIM.
- The user selects one of the following options:
• | Setup SDM Serial Number in DIM, (to continue with the procedure) |
• | Exit, in order to go back to Special Functions menu |
- After the user chooses Setup SDM Serial Number in DIM, the scan
tool displays a screen in the following manner:
• | Do you want to set up a Dash Integration Module? |
• | Press Yes, in order to set up the module. |
• | If the user selects Yes, the scan tool displays Initializing New Module. |
• | Press No, in order to Exit. |
• | If the user selects No, the scan tool display returns to the DIM Special
Function Menu. |
- Once the set up is complete, the scan tool displays Module Initialized.
- In order to complete the procedure, select EXIT: Go to Special
Functions Menu.
- Under the Special Functions menu, one of the choices is Set Options.
- The user selects one of the following options:
• | Set Options, (to continue with the procedure) |
• | Exit, in order to go back to the Special Functions menu |
- Under the Set Options menu, The user selects one of the following
options:
• | Point of Sale, (to continue with the procedure) follow the scan
tool on screen instructions to Select the Point of Sale. |
• | Miscellaneous Options #1, (to continue with the procedure) follow
the scan tool on screen instructions to Select the RPO option configuration. |
• | Miscellaneous Options #2, should be turned ON. |
• | Universal Theft Deterrent, (to continue with the procedure) follow
the scan tool on screen instructions to Select the RPO option configuration. |
• | Automatic/Manual HVAC Options, (to continue with the procedure)
follow the scan tool on screen instructions to Select the RPO option configuration. |
• | MagnaSteer® Option, (to continue with the procedure) follow
the scan tool on screen instructions to Select the RPO option configuration. |
• | Personalization Option, (to continue with the procedure) follow
the scan tool on screen instructions to Select the RPO option configuration. |
• | Exit, to go back to Special Functions menu. |
- Perform the vehicle personalization in order to reset the owner's
desired personalization settings. Refer to Instrument Cluster, Gauges and
Console.
- Cycle the ignition key OFF and ON.
Instrument Panel Module (IPM)
Refer to
Instrument Panel Module Recalibration
in HVAC - Automatic.
Rear Integration Module (RIM)
Before replacing the RIM, record the personalization settings to transfer
to the new module (if they are available).
After replacement of the RIM, perform the following procedure:
- Recalibration of the automatic level control
- Perform the vehicle personalization in order to reset the owner's
desired personalization settings.
Procedure to Set Up A New RIM Module
- Connect a scan tool to the data link connector (DLC).
- Turn ON the ignition, with the engine OFF.
- Under the Chassis Main Menu, select Rear Integration Module.
- Under the Rear Integration Module Main Menu, select Recalibration.
- Follow the scan tool on screen instructions in order to recalibrate
the automatic level control.
- Perform the vehicle personalization in order to reset the owner's
desired personalization settings. Refer to Instrument Cluster, Gauges and
Console.
Important: After programming, perform the following to avoid future misdiagnosis:
- Turn the ignition OFF for 10 seconds.
- Connect the scan tool to the data link connector.
- Turn the ignition ON with the engine OFF.
- Use the scan tool in order to retrieve history DTCs from all modules.
- Clear all history DTCs.