Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Lighting Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Disconnect the stoplamp/auto trans shift lock control switch connector. Did the stoplamps turn off? | -- | Go to Step 4 | Go to Step 3 |
3 | Test for short to power in the brake input circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 6 |
4 | Inspect for poor connections at the stoplamp/auto trans shift lock control switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 5 |
5 | Replace the stoplamp/auto trans shift lock control solenoid switch. Refer to Stop Lamp Switch Replacement in Hydraulic Brakes. Did you complete the replacement? | -- | Go to Step 8 | -- |
6 | Inspect for poor connections at the turn signal/hazard flasher module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 7 |
7 | Replace the turn signal/hazard flasher module. Refer to Hazard Lamp Flasher Replacement . Did you complete the replacement? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you find and correct the condition? | -- | System OK | Go to Step 2 |