Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Lighting Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Did the test lamp illuminate? | -- | Go to Step 3 | Go to Step 6 |
3 | Connect a test lamp between the cornering lamp feed circuit and the cornering lamp ground circuit. Did the test lamp illuminate? | -- | Go to Step 4 | Go to Step 7 |
4 | Inspect for poor connections at the cornering lamp connector. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 5 |
5 | Replace the cornering lamp bulb. Is the replacement complete? | -- | Go to Step 8 | -- |
6 | Repair the open in the cornering lamp feed circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 8 | -- |
7 | Repair the open in the cornering lamp ground circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you find and correct the condition? | -- | System OK | Go to Step 2 |