Step | Action | Yes | No |
---|---|---|---|
DEFINITION: Door locks do not operate from the door lock cylinder switch, mounted on the exterior door key lock cylinder. This test assumes that all DTCs have been diagnosed. | |||
1 | Did you perform the Door Systems Diagnostic System Check and the Power Door Lock System Check? | Go to Step 2 | |
2 |
Does the Driver (or Pass.) Door Lock Sw. parameter change state? | Go to Step 9 | Go to Step 3 |
3 |
Does the Driver (or Pass.) Door Lock Cylinder Sw. parameter change state? | Go to Step 6 | Go to Step 4 |
4 |
Does the Driver (or Pass.) Door Lock Cylinder Sw. parameter change state? | Go to Step 8 | Go to Step 5 |
5 | Test the door lock cylinder switch circuits for an open, short or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 7 |
6 | Inspect for poor connections/terminal tension at the door lock cylinder switch harness connector. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 8 |
7 | Inspect for poor connections/terminal tension at the driver door module (passenger door module) harness connector. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 9 |
8 | Replace the door lock cylinder. Refer to Door Lock Cylinder Replacement . Did you complete the replacement? | Go to Step 10 | -- |
9 | Replace the driver door module. Refer to Door Control Module Replacement . Did you complete the replacement? | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |