Subject: | Tick-Tock Noise From HVAC Module Assembly (Install Spring) |
Models: | 1997-1999 Buick Park Avenue, Ultra with RPO CJ2 |
2000-2001 Buick LeSabre with RPO C67 |
2000-2001 Pontiac Bonneville with RPO C67 |
Some customers may comment that the Heater and Air Conditioning (HVAC) Module Assembly emits a repeating "tick-tock" noise.
The "tick-tock" noise may be due to the two air mix (temperature) actuators on the Park Avenue HVAC module and the mode and air mix (temperature) actuators on the Bonneville and LeSabre HVAC module oscillating/cycling when they have reached a position on the HVAC module.
Install a deflector spring, P/N 25732764, in the covers of the two air mix (temperature) actuators on the Park Avenue HVAC module and in the covers of the mode and air mix (temperature) actuators on the Bonneville and LeSabre HVAC module.
Remove the two air mix (temperature) actuators from the HVAC module assembly. Refer to the Air Mix Actuator -- Driver and the Air Mix Actuator -- Passenger replacement procedures in the HVAC Systems -- Automatic sub-section of the Service Manual.
BONNEVILLE AND LESABRE:
Remove the mode and air mix (temperature) actuators from the HVAC module assembly. Refer to the Mode Actuator and the Temperature Actuator replacement procedures in the HVAC Systems -- Manual sub-section of the appropriate Service Manual.
Tighten
Tighten the screws to 1.4 N·m (12 lb in).
Install the two air mix (temperature) actuators to the HVAC module assembly. Refer to the Air Mix Actuator -- Driver and the Air Mix Actuator -- Passenger replacement procedures in the HVAC Systems -- Automatic sub-section of the Service Manual.
BONNEVILLE AND LESABRE:
Install the mode and air mix (temperature) actuators to the HVAC module assembly. Refer to the Mode Actuator and the Temperature Actuator replacement procedures in the HVAC Systems -- Manual sub-section of the appropriate Service Manual.
Part Number | Description | Qty |
---|---|---|
25732764 | Deflector Spring | 2 |
Parts are currently available from GMSPO.
For vehicles repaired under warranty, use:
Labor Operation | Description | Model | Labor Time |
---|---|---|---|
D4705 | Actuator, Dr & Pass Temperature (Air Mix) Door - R&R, Spring Installation | Park Avenue | 0.8 hr* |
Actuator, Mode & Temperature (Air Mix) Door - R&R, Spring Installation | LeSabre | ||
Bonneville | |||
*This is a unique labor operation to be used only with this bulletin. It will not be published in the Labor Time Guide. |