GM Service Manual Online
For 1990-2009 cars only

Tools Required

J 43600 ACR 2000 Air Conditioning Service Center.

Caution: Avoid breathing the A/C Refrigerant 134a (R-134a) and the lubricant vapor or the mist. Exposure may irritate the eyes, nose, and throat. Work in a well ventilated area. In order to remove R-134a from the A/C system, use service equipment that is certified to meet the requirements of SAE J 2210 (R-134a recycling equipment). If an accidental system discharge occurs, ventilate the work area before continuing service. Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.

Caution: For personal protection, goggles and lint-free gloves should be worn and a clean cloth wrapped around fittings, valves, and connections when doing work that includes opening the refrigerant system. If refrigerant comes in contact with any part of the body severe frostbite and personal injury can result. The exposed area should be flushed immediately with cold water and prompt medical help should be obtained.

Notice: R-134a is the only approved refrigerant for use in this vehicle. The use of any other refrigerant may result in poor system performance or component failure.

Notice: To avoid system damage use only R-134a dedicated tools when servicing the A/C system.

Notice: Use only Polyalkylene Glycol Synthetic Refrigerant Oil (PAG) for internal circulation through the R-134a A/C system and only 525 viscosity mineral oil on fitting threads and O-rings. If lubricants other than those specified are used, compressor failure and/or fitting seizure may result.

Notice: R-12 refrigerant and R-134a refrigerant must never be mixed, even in the smallest of amounts, as they are incompatible with each other. If the refrigerants are mixed, compressor failure is likely to occur. Refer to the manufacturer instructions included with the service equipment before servicing.

The J 43600 is a complete air conditioning service center for R-134a. It recovers, recycles, evacuates and recharges refrigerant quickly, accurately and automatically. The unit has a display screen that contains the function controls as well as displaying prompts that will lead you through the operations. Refrigerant is recovered into and charged out of an internal storage vessel. The ACR 2000 automatically replenishes this vessel from an external source tank in order to maintain a constant 12-15 lbs (5.45-6.82 kg) of refrigerant.

The ACR 2000 has a built--in refrigerant identifier that will check for contaminated refrigerant prior to recovery and will notify you if there is foreign gases present. The unit also features automatic air purge, single pass recycling and automatic oil drain.

Refer to the ACR 2000 manual for operation and setup instruction. Always recharge the A/C System with the proper amount of R-134a. Refer to Refrigerant System Capacities for the correct amount.

Refrigerant System Oil Charge Replenishing

If oil was removed from the A/C system during the recovery process or due to component replacement, the oil must be replenished. For the proper quantities of oil to add to the refrigerant system, refer to Refrigerant System Capacities .