Removal Procedure
- Remove the air temperature actuator. Refer to
Air Temperature Actuator Replacement - Left Side
.
- Disconnect the electrical connector from the mode actuator.
- Remove the IPM. Refer to
Instrument Panel Module Replacement
in Body Control System.
- Remove the mode actuator
retaining screws (1).
- Remove the mode actuator.
Installation Procedure
- Align the mode valve levers
with the cam slots.
- Install the mode actuator.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the mode actuator retaining screws (1).
Tighten
Tighten the fasteners to 1.4 N·m (12 lb in).
- Connect the electrical connector to the mode actuator.
- Install the IPM. Refer to
Instrument Panel Module Replacement
in Body Control System.
- Install the air temperature actuator. Refer to
Air Temperature Actuator Replacement - Left Side
.
- Recalibrate the actuator. Refer to
Actuator Recalibration
.