Removal Procedure
- Remove the case side cover. Refer to
Control Valve Body Cover Replacement .
- Disconnect the transaxle wiring harness.
- Using a small screwdriver or pick, remove the 1-2 shift solenoid valve retainer (314D) from the control valve body (301).
- Remove the 1-2 shift solenoid (315A).
- Remove the O-ring seal (316) from the 1-2 shift solenoid valve (315A) ONLY if it is damaged.
Installation Procedure
- Install a new O-ring seal (316) onto the 1-2 shift solenoid valve (315A), if it was removed.
- Install the 1-2 shift solenoid valve (315A).
- Connect the transaxle wiring harness.
- Hold the 1-2 shift solenoid valve (315A) in the control valve body (301). Install the 1-2 shift solenoid valve retainer (314D) into the control valve body (301).
- Install the case side cover. Refer to
Control Valve Body Cover Replacement .
Important: It is recommended that transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM, PCM or TCM will
need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.
- Reset the TAP values. Refer to
Adapt Function.