Step | Action | Yes | No | ||||||||||||
1 | Were you sent here from the HVAC Symptoms? | Go to Step 2 | Go to Symptoms - HVAC Systems - Manual or Symptoms - HVAC Systems - Automatic | ||||||||||||
2 |
Is a scrape or pop noise evident when selecting modes or temperature settings? | Go to Step 6 | Go to Step 3 | ||||||||||||
3 | Is a tick/click, chirping, groaning or scraping noise present, but decreases as blower motor speed is decreased? | Go to Step 6 | Go to Step 4 | ||||||||||||
4 | Is an air rush/whistle noise evident in all modes but not all temperature settings? | Go to Step 6 | Go to Step 5 | ||||||||||||
5 | Is an air rush/whistle noise evident only in defrost or floor mode? | Go to Step 6 | Go to Step 7 | ||||||||||||
6 | Remove the IP trim pad. Refer to Instrument Panel Upper Trim Pad Replacement in Instrument Panel, Gages and Console. Is the action complete? | Go to Step 7 | -- | ||||||||||||
7 |
Were any of these conditions found? | Go to Step 13 | Go to Step 8 | ||||||||||||
8 | Inspect the mode and temperature doors for warping or cracking. Are the doors in normal condition? | Go to Step 9 | Go to Step 11 | ||||||||||||
9 | Inspect the HVAC ducts for any obstructions or foreign material. Were any obstructions found? | Go to Step 13 | Go to Step 10 | ||||||||||||
10 | Inspect the temperature doors seals. Are the door seals in good condition? | Go to Step 14 | Go to Step 11 | ||||||||||||
11 | Replace the appropriate door seals. Is the repair complete? | Go to Step 14 | -- | ||||||||||||
12 | Replace the appropriate door. Is the repair complete? | Go to Step 14 | -- | ||||||||||||
13 | Remove any obstructions or foreign material found. Is the action complete? | Go to Step 14 | -- | ||||||||||||
14 | Install the IP trim pad. Refer to Instrument Panel Upper Trim Pad Replacement in Instrument Panel, Gages and Console. Is the action complete? | Go to Step 15 | -- | ||||||||||||
15 | Operate the system to verify the repair. Does the system operate correctly? | System OK | Go to Step 2 |