GM Service Manual Online
For 1990-2009 cars only

Step

Action

Values

Yes

No

Schematic Reference: HVAC Schematics

Connector End View Reference: HVAC Connector End Views

DEFINITION: The temperature cannot be adjusted, or the cooling is insufficient during A/C operation.

1

Did you perform the HVAC Diagnostic System Check?

--

Go to Step 2

Go to Diagnostic System Check - HVAC Systems - Automatic

2

  1. Install a scan tool.
  2. Turn ON the ignition, with the engine OFF.
  3. With a scan tool, perform the Recalibrate all Motors command in instrument panel module (IPM) Special Functions.
  4. With a scan tool, observe the current DTC list in the IPM.

Does the scan tool display any DTCs?

--

Go to Diagnostic Trouble Code (DTC) List

Go to Step 3

3

Place the blower motor switch in each speed position.

Does the blower motor operate in any of the speed positions?

--

Go to Step 4

Go to Blower Motor Inoperative

4

Does the blower motor operate in each speed position?

--

Go to Step 5

Go to Blower Motor Malfunction

5

Important:: Ambient air temperature must be above 3°C (38°F).

  1. Cover the sunload sensor assembly.
  2. Start the engine.
  3. Fully open all panel outlets.
  4. Place the temperature switch in the coldest position.
  5. Place the mode switch in the panel position.
  6. Place the blower motor switch in the maximum speed position.
  7. Ensure that the vent, ambient air, indicator is not illuminated.

Does the A/C compressor operate?

--

Go to Step 6

Go to HVAC Compressor Clutch Does Not Engage

6

Perform the A/C system performance test.

Refer to Air Conditioning (A/C) System Performance Test in Heating, Ventilation and Air Conditioning.

Did you find and correct the condition?

--

Go to Step 22

Go to Step  7

7

Inspect the temperature sensors for proper installation. Refer to the following procedures:

Did you find and correct the condition?

--

Go to Step 22

Go to Step 8

8

  1. Start the engine.
  2. Fully open all panel outlets.
  3. Place the temperature switch in the 24°C (75°F) position.
  4. Place the mode switch in the panel position.
  5. Set blower speed to illuminate 2 bars on the fan speed indicator.
  6. Place the right air temperature switch assembly in the neutral position.
  7. Inspect for airflow through the inside air temperature sensor by placing a 5 cm (2 in) square piece of paper over the sensor air inlet.

Does the paper stay in place?

--

Go to Step 9

Go to Step 13

9

  1. Turn the engine OFF.
  2. Install a scan tool.
  3. Cover the sunload sensor assembly.
  4. Start the engine.
  5. Place the temperature switch in the 24°C (75°F) position.
  6. Place the right air temperature switch assembly in the neutral position.
  7. With a scan tool, observe the Right and Left Solar Sensor data parameters in the IPM Open/Short Data list.

Does the scan tool indicate that the Right and Left Solar Sensor data parameters are more than the specified value?

224 Counts

Go to Step 10

Go to Step 17

10

  1. Uncover the sunload sensor assembly.
  2. Direct a light source at the right and then the left side of the sunload sensor assembly.

Do the counts change similarly and correspond to the proper side of the sunload sensor assembly?

--

Go to Step 11

Go to Step 17

11

  1. Install a thermometer near the following air temperature sensors:
  2. • Inside
    • Upper right
    • Upper left
    • Lower right
    • Lower left
  3. With a scan tool, observe the following data parameters in the IPM HVAC Sensor data list:
  4. • Inside Air Temp
    • Right AC Duct Temp
    • Left AC Duct Temp
    • Right Htr. Duct Temp
    • Left Htr. Duct Temp

Does the scan tool indicate sensor temperatures near the thermometer temperatures within the specified range?

+3 to -3°C

(+5 to -5°F)

Go to Step 12

Go to Step 14

12

Does the customer need to change the set temperature frequently to maintain comfort?

--

Go to Air Conditioning (A/C) System Does Not Maintain Set Temperature

Go to Step 16

13

Inspect for a blocked or disconnected aspiration hose.

Did you find and correct the condition?

--

Go to Step 22

--

14

Inspect for poor connections at the harness connector of the suspect temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 22

Go to Step 15

15

Test the suspect temperature sensor resistance. Refer to Sensor Resistance Table .

Does the resistance measure near the Sensor Resistance Table value?

--

Go to Step 18

Go to Step 19

16

  1. Install a scan tool.
  2. Turn ON the ignition, with the engine OFF.
  3. With a scan tool, adjust the Temperature Offset in IPM Special Function/Set Options as needed.

Did you complete the repair?

--

Go to Step 22

--

17

Inspect for poor connections at the harness connector of the sunload sensor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 22

Go to Step 20

18

Inspect for poor connections at the harness connector of the IPM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 22

Go to Step 21

19

Replace the suspect temperature sensor. Refer to the following procedures:

Did you complete the replacement?

--

Go to Step 22

--

20

Replace the sunload sensor assembly. Refer to Sunload and Twilight Sentinel Sensor Replacement in Instrument Panel, Gages, and Console.

Did you complete the replacement?

--

Go to Step 22

--

21

Important: : Perform the Recalibration procedure for the instrument panel integration module.

Replace the instrument panel integration module. Refer to Instrument Panel Module Replacement in Body Control System.

Did you complete the replacement?

--

Go to Step 22

--

22

Operate the system in order to verify the repair.

Did you correct the condition?

--

System OK

Go to Step 2