Step | Action | Values | Yes | No | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or the cooling is insufficient during A/C operation. | ||||||||||||||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |||||||||||||||||||||
2 |
Does the scan tool display any DTCs? | -- | Go to Step 3 | |||||||||||||||||||||
3 | Place the blower motor switch in each speed position. Does the blower motor operate in any of the speed positions? | -- | Go to Step 4 | Go to Blower Motor Inoperative | ||||||||||||||||||||
4 | Does the blower motor operate in each speed position? | -- | Go to Step 5 | Go to Blower Motor Malfunction | ||||||||||||||||||||
5 |
Important:: Ambient air temperature must be above 3°C (38°F).
Does the A/C compressor operate? | -- | Go to Step 6 | |||||||||||||||||||||
6 | Perform the A/C system performance test. Refer to Air Conditioning (A/C) System Performance Test in Heating, Ventilation and Air Conditioning. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 7 | ||||||||||||||||||||
7 | Inspect the temperature sensors for proper installation. Refer to the following procedures: Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 8 | ||||||||||||||||||||
8 |
Does the paper stay in place? | -- | Go to Step 9 | Go to Step 13 | ||||||||||||||||||||
9 |
Does the scan tool indicate that the Right and Left Solar Sensor data parameters are more than the specified value? | 224 Counts | Go to Step 10 | Go to Step 17 | ||||||||||||||||||||
10 |
Do the counts change similarly and correspond to the proper side of the sunload sensor assembly? | -- | Go to Step 11 | Go to Step 17 | ||||||||||||||||||||
11 |
Does the scan tool indicate sensor temperatures near the thermometer temperatures within the specified range? | +3 to -3°C (+5 to -5°F) | Go to Step 12 | Go to Step 14 | ||||||||||||||||||||
12 | Does the customer need to change the set temperature frequently to maintain comfort? | -- | Go to Air Conditioning (A/C) System Does Not Maintain Set Temperature | Go to Step 16 | ||||||||||||||||||||
13 | Inspect for a blocked or disconnected aspiration hose. Did you find and correct the condition? | -- | Go to Step 22 | -- | ||||||||||||||||||||
14 | Inspect for poor connections at the harness connector of the suspect temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 15 | ||||||||||||||||||||
15 | Test the suspect temperature sensor resistance. Refer to Sensor Resistance Table . Does the resistance measure near the Sensor Resistance Table value? | -- | Go to Step 18 | Go to Step 19 | ||||||||||||||||||||
16 |
Did you complete the repair? | -- | Go to Step 22 | -- | ||||||||||||||||||||
17 | Inspect for poor connections at the harness connector of the sunload sensor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 20 | ||||||||||||||||||||
18 | Inspect for poor connections at the harness connector of the IPM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 21 | ||||||||||||||||||||
19 | Replace the suspect temperature sensor. Refer to the following procedures: Did you complete the replacement? | -- | Go to Step 22 | -- | ||||||||||||||||||||
20 | Replace the sunload sensor assembly. Refer to Sunload and Twilight Sentinel Sensor Replacement in Instrument Panel, Gages, and Console. Did you complete the replacement? | -- | Go to Step 22 | -- | ||||||||||||||||||||
21 |
Important: : Perform the Recalibration procedure for the instrument panel integration module. Replace the instrument panel integration module. Refer to Instrument Panel Module Replacement in Body Control System. Did you complete the replacement? | -- | Go to Step 22 | -- | ||||||||||||||||||||
22 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |