Step | Action | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the air distribution outlets. | |||||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |||||||||||||
2 |
Is the blower motor OFF? | Go to Step 3 | Go to Blower Motor Always On | ||||||||||||
3 | Place the blower motor switch in each speed position. Does the blower motor operate in any of the speed positions? | Go to Step 4 | Go to Blower Motor Inoperative | ||||||||||||
4 | Does the blower motor operate in each speed position? | Go to Step 5 | Go to Blower Motor Malfunction | ||||||||||||
5 |
Does the recirculation door move from the recirculation position to the ambient air position? | Go to Step 6 | |||||||||||||
6 |
Does the scan tool display any DTCs? | Go to Step 7 | |||||||||||||
7 | Place the mode switch in each position. Does the display on the HVAC control module respond correctly to changes in mode selection? | Go to Step 8 | Go to Step 14 | ||||||||||||
8 | Place the mode switch and defrost switch in each mode position? Is the airflow sufficient from the correct outlets in each mode? | Go Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 9 | ||||||||||||
9 |
Does the scan tool indicate that the Htr./Def./A/C Dr. Commanded parameter changes for each change in selected mode position? | Go to Step 10 | Go to Step 15 | ||||||||||||
10 | Test the ignition 3 voltage circuit and the low reference circuit of the mode actuator for high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 11 | ||||||||||||
11 | Inspect the air distribution system for the following conditions:
Did you find and correct the condition? | Go to Step 19 | Go to Step 12 | ||||||||||||
12 | Inspect the mode door and the mode actuator for the following conditions:
Did you find and correct the condition? | Go to Step 19 | Go to Step 13 | ||||||||||||
13 | Inspect for poor connections at the harness connector of the mode actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 16 | ||||||||||||
14 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 17 | ||||||||||||
15 | Inspect for poor connections at the harness connector of the instrument panel integration module (IPM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 18 | ||||||||||||
16 |
Important: Perform the recalibration procedure for the mode actuator. Replace the mode actuator. Refer to Mode Actuator Replacement . Did you complete the replacement? | Go to Step 19 | -- | ||||||||||||
17 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | Go to Step 19 | -- | ||||||||||||
18 |
Important: Perform the Recalibration procedure for the instrument panel integration module (IPM). Replace the instrument panel integration module (IPM). Refer to Instrument Panel Module Replacement in Body Control System. Did you complete the replacement? | Go to Step 19 | -- | ||||||||||||
19 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |