Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Control head illumination/display does not operate properly. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Does the scan tool display any DTCs? | Go to Step 3 | |
3 | When performing the Diagnostic System Check, was DTC B2646 displayed for the Instrument Panel Module? | Go to Diagnostic Trouble Code (DTC) List in Lighting Systems | Go to Step 4 |
4 |
Do all HVAC control module segments illuminate? | Go to Step 5 | Go to Step 8 |
5 | When performing the Display Test Instrument Panel Module command, do all other VF displays illuminate? | Go to Step 6 | Go to Symptoms - Lighting Systems in Lighting Systems |
6 |
Is there backlighting? | Go to Step 7 | Go to Symptoms - Lighting Systems in Lighting Systems |
7 | Adjust the dimming control from minimum intensity to maximum intensity. Does the VF display decrease and increase in intensity? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 8 |
8 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 9 |
9 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the repair? | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |