- Remove the water pump drive belt shield
bolt and nuts.
- Remove the water pump drive belt shield.
- Remove the water pump drive belt by compressing
the belt tensioner while sliding the belt off the drive pulley and the water pump
pulley.
- Remove the water pump drive belt tensioner
bolts from the tensioner.
- Remove the water pump drive belt tensioner from the water crossover.
- Remove the crankshaft position sensor and knock sensor
wiring harness bracket bolt.
- Loosen the water crossover mounting bolts.
- Remove the water crossover and all mounting bolts.
- Remove the water crossover gaskets and mounting
bolts from the water crossover.