Engine Ground Cable Replacement RPO LD8
Removal Procedure
Important:
• | Always use replacement cables that are of the same type, diameter and length of the cables that you are replacing. |
• | Always route the replacement cable the same way as the original cable. |
- Remove the front compartment sight shield. Refer to
Front Compartment Sight Shields Replacement
.
- Remove the bolt (1) securing the engine ground cable (2) to the right side body frame rail.
- Remove the rear generator bolt.
- Remove the engine ground cable.
Installation Procedure
- Position the engine ground cable to the generator.
Notice: Refer to Fastener Notice in the Preface section.
- Install the rear generator bolt.
Tighten
Tighten the bolt to 50 N·m (37 lb ft).
- Install the bolt (1) securing the engine ground cable (2) to the right side body frame rail.
Tighten
Tighten the bolt to 25 N·m (18 lb ft).
- Install the front compartment sight shield. Refer to
Front Compartment Sight Shields Replacement
.