Removal Procedure
Caution: Fuel Vapors can collect while servicing fuel system parts in enclosed
areas such as a trunk. To reduce the risk of fire and increased exposure to
vapors:
• | Use forced air ventilation such as a fan set outside
of the trunk. |
• | Plug or cap any fuel system openings in order to reduce fuel vapor
formation. |
• | Clean up any spilled fuel immediately. |
• | Avoid sparks and any source of ignition. |
• | Use signs to alert others in the work area that fuel system work
is in process. |
- Remove the fuel pump module. Refer to
Fuel Sender Assembly Replacement
.
- Release the fuel level sensor electrical connector clip.
- Disconnect the fuel level sensor electrical connector (1) from under the fuel module cover.
- Release the locking tab (2) and slide the fuel level sensor (3) down off of the bucket.
Installation Procedure
- Slide the fuel level sensor (3) up onto the bucket, gently lift up on the locking tab (2) and continue sliding the sensor up until
it engages the tab.
- Connect the fuel level sensor electrical connector (1) under the module cover. Push up the connector until the clip engages.
- Install the fuel pump module. Refer to
Fuel Sender Assembly Replacement
.