A/C Clutch--Actual: The scan tool displays On/Off. The
HVAC control module displays On when the engine control module (ECM) transmits a class 2
message that the A/C compressor clutch relay is energized.
A/C Clutch--Desired: The scan tool displays Yes/No. The
scan tool displays Yes when the HVAC control module determines that conditions for
compressor clutch engagement are present.
A/C High Side Pressure : The scan tool displays 0-3450 kPa
(0-500 psi). The voltage applied to the ECM input from the A/C refrigerant
pressure sensor is converted to a pressure value.
A/C High Side Pressure : The scan tool displays 0-5 volts.
The voltage applied to the ECM input for the A/C refrigerant pressure sensor.
A/C Pressure: The scan tool displays 0-3450 kPa
(0-500 psi). The voltage applied to the ECM input from the A/C refrigerant
pressure sensor is converted to a pressure value and transmitted in a class 2
message to the HVAC control module.
A/C Relay Command: The scan tool displays On/Off. The scan tool
displays the control decision for the compressor clutch relay output as determined
by the ECM.
A/C Request Signal: The scan tool displays Yes/No. The scan
tool displays Yes when the ECM receives a class 2 message from the HVAC control
module to engage the A/C compressor clutch. The scan tool displays No when the ECM
receives a class 2 message from the HVAC control module to disengage the A/C
compressor clutch.
Commanded Blower: The scan tool displays 0-100%. The scan
tool displays the control decision for the blower motor speed as determined by the
HVAC control module. The scan tool displays 100% when the blower motor is commanded
to maximum speed. The scan tool displays 0% when the blower motor is commanded OFF.
Coolant Temperature: The scan tool displays -39 to +140°C
(-38 to +284°F) . The voltage applied to the ECM input from the engine coolant
temperature sensor is converted to a temperature value and transmitted in a class 2
message to the HVAC control module.
Driver Temp Dr. Actual: The scan tool displays 0-255 counts
(0-5.00 volts). The voltage applied to the driver air temperature door
position input of the HVAC control module.
Driver Temp Dr. Commanded: The scan tool displays 0-255 counts
(0-5.00 volts). The desired position of the driver air temperature actuator
as determined by the HVAC control module.
Driver Solar Sensor: The scan tool displays 0-255 counts
(0-5.00 volts). The voltage applied to the driver sunload input of the
HVAC control module.
Driver Sunload: The scan tool displays 0-2000 w/m2.
The voltage applied to the driver sunload input of the HVAC control module converted
to light intensity units.
ECT Sensor: The scan tool displays -39 to +140°C (-38
to +284°F) . The voltage applied to the ECM input from the engine coolant temperature
sensor is converted to a temperature value.
ECT Sensor: The scan tool displays 0-5 volts. The voltage
applied to the ECM input for the engine coolant temperature sensor.
Evaporator Temp: The scan tool displays -39 to +140°C
(-38 to +284°F). The voltage applied to the HVAC control module input from
the evaporator temperature sensor is converted to a temperature value.
Evaporator Temp: The scan tool displays 0-255 counts
(0-5 volts). The voltage applied to the HVAC control module input for the evaporator
temperature sensor.
Inside Air Temp.: The scan tool displays -40 to +215°C
(-40 to +419°F). The voltage applied to the HVAC control module input for
the inside air temperature sensor is converted to a temperature value.
Inside Air Temp.: The scan tool displays 0-255 counts
(0-5.00 volts). The voltage applied to the HVAC control module input
for the inside air temperature sensor.
Low Coolant Status: The scan tool displays OK/Low. The filtered
state of the low coolant switch.
Low Coolant Switch: The scan tool displays Open/Closed. The
actual state of the low coolant switch.
Mode Dr. Actual: The scan tool displays 0-255 counts
(0-5.00 volts). The voltage applied to the mode door position input of
the HVAC control module.
Mode Dr. Commanded: The scan tool displays 0-255 counts
(0-5.00 volts). The desired position of the mode actuator as determined
by the HVAC control module.
Outside Air Temp. : The scan tool displays -40
to +215°C (-40 to +419°F). The current value of the ambient air temperature
display on the HVAC control module.
Outside Air Temp. : The scan tool displays 0-255 counts
(0-5.00 volts). The voltage applied to the HVAC control module input
for the outside air temperature sensor.
Passenger Solar Sensor: The scan tool displays 0-255 counts
(0-5.00 volts). The voltage applied to the passenger sunload input of
the HVAC control module.
Passenger Sunload: The scan tool displays 0-2000 w/m2.
The voltage applied to the driver sunload input of the HVAC control module converted
to light intensity units.
Passenger Temp Dr. Actual: The scan tool displays 0-255 counts
(0-5.00 volts). The voltage applied to the passenger air temperature
door position input of the HVAC control module.
Passenger Temp Dr. Commanded: The scan tool displays 0-255 counts
(0-5.00 volts). The desired position of the passenger air temperature
actuator as determined by the HVAC control module.
Pressure Sensor: The scan tool displays OK/Failed. The state
of the A/C refrigerant pressure sensor and circuitry.