The numbers below refer to the step numbers on the diagnostic table.
This test resets the HVAC control module and checks for current air temperature actuator DTC.
Ambient air temperature must be above 3°C (38°F) in order for this A/C Compressor test to be run.
Step | Action | Values | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or cooling is insufficient during the A/C operation. | ||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |||||||||
Does the scan tool display DTC B0408, B0409, B0419 or B0423? | -- | Go to Step 3 | ||||||||||
3 | Place the blower motor switch in each speed position. Does the blower motor operate in any speed position? | -- | Go to Step 4 | Go to Blower Motor Malfunction | ||||||||
4 | Does the blower motor operate in each speed position? | -- | Go to Step 5 | Go to Blower Motor Malfunction | ||||||||
5 |
Does the recirculation door move from the recirculation position to the ambient air position? | -- | Go to Step 6 | Go to Air Delivery Improper | ||||||||
6 | Place the passenger temperature in the OFF position. Does the Too Hot in Vehicle concern occur when A/C cooling desired? | -- | Go to Step 7 | Go to Step 9 | ||||||||
Important: Ambient air temperature must be above 3°C (38°F).
Does the A/C compressor operate? | -- | Go to Step 8 | ||||||||||
8 | Perform the A/C system performance test. Refer to Air Conditioning (A/C) System Performance Test . Did you find and correct the condition? | -- | Go to Step 26 | Go to Step 9 | ||||||||
9 | Inspect the upper left, upper right, lower left, and lower right air temperature sensors for the following conditions:
Did you find and correct the condition? | -- | Go to Step 26 | Go to Step 10 | ||||||||
10 |
Does the paper stay in place? | -- | Go to Step 11 | Go to Step 14 | ||||||||
11 |
Does the scan tool indicate that the sensor temperatures are within the specifications at the thermometer temperatures? | -3 to +3°C (-5 to +5°F) | Go to Step 12 | Go to Step 17 | ||||||||
12 |
Does the scan tool indicate that the solar sensor parameter is greater than the specified value? | 224 Counts | Go to Step 13 | Go to Step 19 | ||||||||
13 |
Do the counts change? | -- | System OK | Go to Step 19 | ||||||||
14 |
Does the test lamp illuminate? | -- | Go to Step 18 | Go to Step 15 | ||||||||
15 | Test the ignition 3 voltage circuit of the inside air temperature assembly for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 26 | Go to Step 16 | ||||||||
16 | Test the inside air temperature assembly control circuit of the inside air temperature assembly for the following conditions:
Did you find and correct the condition? | -- | Go to Step 26 | Go to Step 20 | ||||||||
17 | Test the suspect temperature sensor resistance. Does the resistance measure near the Sensor Resistance Table? | -- | Go to Step 21 | Go to Step 18 | ||||||||
18 | Inspect for poor connections at the harness connector of the air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 26 | Go to Step 22 | ||||||||
19 | Inspect for poor connections at the harness connector of the sunload sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 26 | Go to Step 23 | ||||||||
20 | Inspect for poor connections at the harness connector of the HVAC module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 26 | Go to Step 24 | ||||||||
21 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 26 | Go to Step 25 | ||||||||
22 | Replace the temperature sensor. Refer to Inside Air Temperature Sensor Replacement . Did you complete the replacement? | -- | Go to Step 26 | -- | ||||||||
23 | Replace the sunload sensor. Refer to Sun Load Sensor Replacement . Did you complete the replacement? | -- | Go to Step 26 | -- | ||||||||
24 | Replace the HVAC module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 26 | -- | ||||||||
25 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 26 | -- | ||||||||
26 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |