Fuel Level Sensor Wiring Harness Replacement RPO NT7
Removal Procedure
- Remove the fuel tank. Refer to
Fuel Tank Replacement
.
- Disconnect the fuel level sensor wiring harness electrical connectors
from the pressure sensor and module.
- Remove the fuel level sensor wiring harness.
Installation Procedure
- Install the fuel level sensor wiring harness.
- Connect the fuel level sensor wiring harness electrical connectors to
the pressure sensor and module.
- Install the fuel tank. Refer to
Fuel Tank Replacement
.
Fuel Level Sensor Wiring Harness Replacement RPO NU6
Removal Procedure
- Remove the fuel tank. Refer to
Fuel Tank Replacement
.
- Cut the tape (1 and 2) securing the fuel tank vent line to the fuel feed
line.
- Remove the retainer (3) from the vent and fuel feed lines.
- Disconnect the fuel feed line quick connect
fitting from the module. Refer to
Plastic Collar Quick Connect Fitting Service
.
- Remove the fuel feed line.
- Disconnect the fuel tank vent line quick
connect fittings from the module. Refer to
Plastic Collar Quick Connect Fitting Service
.
- Remove the fuel tank vent lines.
- Disconnect the fuel tank electrical harness
connector from the module.
- Remove the electrical harness from the retaining features on the fuel
tank.
- Remove the electrical harness.
Installation Procedure
- Install the electrical harness.
- Connect the fuel tank electrical harness connector to the module.
- Install the electrical harness to the retaining features on the fuel tank.
- Install the fuel tank vent lines.
- Connect the fuel tank vent line quick connect fittings to the module.
Refer to
Plastic Collar Quick Connect Fitting Service
.
- Install the fuel feed line.
- Connect the fuel feed line quick connect fitting to the module. Refer
to
Plastic Collar Quick Connect Fitting Service
.
- Install the retainer (3) to the vent and fuel feed
lines.
- Install tape (1 and 2) to the fuel tank vent and fuel feed line in order
to secure the lines.
- Install the fuel tank. Refer to
Fuel Tank Replacement
.