Removal Procedure
- Remove the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement
.
- Remove the exhaust gas recirculation (EGR) valve outlet pipe bolt from the intake manifold.
- Remove the EGR valve outlet pipe nut from the EGR valve adapter.
- Remove the EGR valve outlet pipe.
Installation Procedure
- Install the EGR valve outlet pipe.
Notice: Refer to Fastener Notice in the Preface section.
- Install the EGR valve outlet pipe bolt to the intake manifold.
Tighten
Tighten the bolt to 25 N·m (18 lb ft).
- Install the EGR valve outlet pipe nut to the EGR valve adapter.
Tighten
Tighten the nut to 25 N·m (18 lb ft).
- Install the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement
.