• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
B+, BCM C4 Terminal 1 | 2 | 2 | -- | -- |
Brake Apply Sensor Supply Voltage | C0870 03 | C0870 03 | C0870 07 | -- |
Brake Apply Sensor Signal | C0277 06 | C0277 06 | C0277 07 | C0277 09 |
Brake Pedal Position Sensor Low Reference | -- | 1 | -- | -- |
Stop Lamp Switch Signal | C0297 00 | -- | -- | -- |
CHMSL Supply Voltage | B3445 00 | 4 | 4 | -- |
Left Rear Stop/Turn Lamp Supply Voltage | 2 | 2 | 2 | -- |
Right Rear Stop/Turn Lamp Supply Voltage | 3 | 3 | 3 | -- |
Center High Mounted Stop Lamp (CHMSL) Ground | -- | 4 | -- | -- |
Left Rear Stop/Turn Lamp Ground | -- | 2 | -- | -- |
Right Rear Stop/Turn Lamp Ground | -- | 3 | -- | -- |
|
The brake pedal position sensor is used to sense the action of the driver application of the brake pedal. The brake pedal position sensor provides an analog voltage signal that will increase as the brake pedal is applied. The body control module (BCM) provides a low reference signal and a 5-volt reference voltage to the brake pedal position sensor. When the variable signal reaches a voltage threshold indicating the brakes have been applied, the BCM will apply battery positive voltage to the stop lamps, center high mounted stop lamp (CHMSL), transmission control module (TCM), and engine control module (ECM). The stop lamps will not operate unless the ignition is in the ON position. Ground for the left stop/tail lamp assembly is provided by G402 and ground for the right stop/tail lamp assembly is provided by G403.
Important: The stop lamps will not illuminate unless the ignition is in the ON position. For more detailed information concerning stop lamp operation, refer to Exterior Lighting Systems Description and Operation.
Lighting Systems Connector End Views
• | B+ terminal 1 |
• | B+ terminal 2 |
• | B+ terminal 4 |
⇒ | If the test lamp does not illuminate, test the B+ circuit for an open/high resistance. If the circuit fuse is open, test the B+ circuit and the respective stop lamp circuits for a short to ground. |
⇒ | If the test lamp does not illuminate, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp is always ON, test the supply voltage circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the supply voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp is always ON, test the supply voltage circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the supply voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |