Removal Procedure
Important: DO NOT
remove the screws from the upper air cleaner cover.
- Loosen the air cleaner cover screws (1).
- Disconnect the secondary air injection (AIR) hose
quick connect fitting (1) from the air cleaner, if equipped. Refer to
Plastic Collar Quick Connect Fitting Service
.
- Open the air cleaner cover.
- Remove the air filter from the air cleaner.
Important: The air cleaner cover has a hydro carbon
adsorber that is not serviceable. If the adsorber shows any kind of physical damage
the cover must be replaced.
- Inspect the air cleaner housing assembly for damage. If a problem is found,
replace as necessary.
Installation Procedure
- Install the air filter to the air cleaner.
- Close the air cleaner cover. Ensure that the inboard hinges are engaged
prior to tightening the screws.
- Connect the AIR hose quick connect fitting (1) to
the air cleaner, if equipped. Refer to
Plastic Collar Quick Connect Fitting Service
.
Notice: Refer to Fastener Notice in the Preface section.
- Tighten the air cleaner cover screws (1).
Tighten
Tighten the screws to 3 N·m (27 lb in).