GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptor

DTC B2750 00: Horn Relay Coil Circuit

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Horn Relay Control

B2750 00

B2750 00

B2750 00

--

Horn Control

2

2

1

--

Horn Switch Ground

--

2

2

--

Horn Ground

--

2

2

--

1. Horn Always ON

2. Horn Inoperative

Circuit/System Description

The body control module (BCM) controls the HORN relay by grounding the control circuit of the horn relay coil energizing the relay. When the HORN relay is energized, the horn relay contacts close applying voltage through the HORN fuse and the horn control circuit to the horns.

Conditions for Running the DTC

When the output is actively being requested by the BCM.

Conditions for Setting the DTC

The BCM detects a short to ground, open, or short to voltage in the horn relay control circuit for approximately 125 milliseconds.

Action Taken When the DTC Sets

The BCM disables the output to the HORN relay until the next ignition cycle.

Conditions for Clearing the DTC

    • The DTC clears when the fault is no longer detected.
    • The current DTC will become history when the request for the output is removed.
    • The history DTC will clear after 50 consecutive fault-free ignition cycles have occurred.

Reference Information

Schematic Reference

Horn Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Horns System Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Verification

Command the horns ON and OFF with the scan tool. The horns should turn ON and OFF when changing between the commanded states.

Circuit/System Testing

  1. Ignition OFF, disconnect the X2 harness connector at the underhood fuse block.
  2. Connect a test lamp between B+ and the control circuit terminal 26.
  3. Press and release the horn switch. The test lamp should turn ON and OFF when changing between the commanded states.
  4. If the test lamp is always ON, test the control circuit for a short to ground or a sticking horn switch. If the circuit tests normal, replace the BCM.
    If the test lamp is always OFF, test the control circuit for a short to voltage, an open high resistance, or a horn switch which is not closing. If the circuit tests normal, replace the BCM.
  5. If all circuits test normal, replace the underhood fuse block.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Underhood Electrical Center or Junction Block Replacement
    •  Control Module References for BCM replacement, setup and programming