GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptor

DTC P0230: Fuel Pump Relay Control Circuit

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Battery Voltage - Relay Switch Side

¹

²

--

--

Fuel Pump Supply Voltage

¹

²

³

--

Fuel Pump Relay Control

P0230

P0230

P0230

--

Fuel Pump Relay Ground

--

P0230

--

--

Fuel Pump Ground

--

²

--

--

¹Blown fuel pump fuse, cranks no start

²Cranks, no start

³Fuel pump operates continuously, then discharged battery

Circuit/System Description

The control module enables the fuel pump relay when the ignition switch is turned ON. The control module will disable the fuel pump relay within 2 seconds unless the control module detects ignition reference pulses. The control module continues to enable the fuel pump relay as long as ignition reference pulses are detected. The control module disables the fuel pump relay within 2 seconds if ignition reference pulses cease to be detected and the ignition remains ON.

The control module monitors the voltage on the fuel pump relay control circuit. If the control module detects an incorrect voltage on the fuel pump relay control circuit, a fuel pump relay control DTC sets.

Conditions for Running the DTC

    • The ignition is ON.
    • The system voltage is between 9-18 volts.
    • DTC P0230 runs continuously when the above conditions are met.

Conditions for Setting the DTC

    • The control module detects that the commanded state of the driver and the actual state of the control circuit do not match.
    • The above condition is met for a minimum of 2.5 seconds.

Action Taken When the DTC Sets

DTC P0230 is a Type B DTC

Conditions for Clearing the MIL/DTC

DTC P0230 is a Type B DTC

Reference Information

Schematic Reference

Engine Controls Schematics

Connector End View Reference

Component Connector End Views

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

DTC Type Reference

Powertrain Diagnostic Trouble Code (DTC) Type Definitions

Scan Tool Reference

Control Module References for scan tool information

Special Tools

J 43244 Relay Puller Pliers

Circuit/System Verification

Note: An open or a short to voltage in the control circuit will cause both the Ckt. Open Test Status and the Ckt. Short Volts Test Status parameters to display Fault.

    • Ignition ON, command the fuel pump relay ON and OFF with a scan tool while observing the following control circuit status parameters:
       - Fuel Pump Relay Ckt. Short Gnd Test Status
       - Fuel Pump Relay Ckt. Open Test Status
       - Fuel Pump Relay Ckt. Short Volts Test Status
    • Each parameter should toggle between OK and Not Run or Not Run and OK.

Circuit/System Testing

  1. With the ignition OFF, remove the fuel pump relay from the rear electrical center using the J 43244 Puller Pliers .
  2. With the ignition ON, engine OFF, probe control circuit terminal 3 of the fuel pump relay with a test lamp that is connected to a ground. Command the fuel pump relay ON and OFF with a scan tool. The test lamp should turn ON and OFF with each command.
  3. If the test lamp does not turn ON and OFF, test for an open or a short to ground in the fuel pump relay control circuit or an intermittent or a poor connection at the engine control module (ECM). If the circuit tests normal, replace the control module.
    If the test lamp remains illuminated with each command, test for a short to voltage in the control circuit of the fuel pump relay or an intermittent or a poor connection at the ECM. If the circuit tests normal, replace the control module.
  4. Connect a test lamp between control circuit terminal 3 of the fuel pump relay and ground circuit terminal 4 of the fuel pump relay. Command the fuel pump relay ON and OFF with a scan tool.
  5. If the test lamp does not turn ON and OFF, repair the open or the high resistance in the ground circuit of the fuel pump relay.
    If the test lamp does turn ON and OFF, test for an intermittent and for a poor connection at the fuel pump relay, or a faulty fuel pump relay.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Relay Replacement
    •  Control Module References for ECM replacement, setup, and programming