Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-65°F) | 0-100% | 130-227 kPa (19-33 psi) | 482-799 kPa (70-116 psi) | 9°C (48°F) |
19-24°C (66-75°F) | Below 40% | 130-234 kPa (19-34 psi) | 613-950 kPa (89-138 psi) | 10°C (50°F) |
Above 40% | 130-254 kPa (19-37 psi) | 661-999 kPa (96-145 psi) | 13°C (54°F) | |
25-29°C (76-85°F) | Below 35% | 179-254 kPa (26-37 psi) | 840-1123 kPa (122-163 psi) | 13°C (54°F) |
35-50% | 192-261 kPa (28-38 psi) | 861-1129 kPa (125-164 psi) | 13°C (55°F) | |
Above 50% | 199-268 kPa (29-39 psi) | 881-1157 kPa (128-168 psi) | 14°C (57°F) | |
30-35°C (86-95°F) | Below 30% | 206-282 kPa (30-41 psi) | 1019-1329 kPa (148-193 psi) | 15°C (59°F) |
30-50% | 213-289 kPa (31-42 psi) | 1040-1336 kPa (151-194 psi) | 15°C (59°F) | |
Above 50% | 220-289 kPa (32-42 psi) | 1047-1357 kPa (152-197 psi) | 18°C (63°F) | |
36-41°C (96-105°F) | Below 20% | 234-310 kPa (34-45 psi) | 1240-1550 kPa (180-225 psi) | 18°C (63°F) |
20-40% | 241-310 kPa (35-45 psi) | 1247-1550 kPa (181-225 psi) | 18°C (64°F) | |
Above 40% | 241-310 kPa (35-45 psi) | 1260-1550 kPa (183-225 psi) | 19°C (66°F) | |
42-46°C (106-115°F) | Below 20% | 268-337 kPa (39-49 psi) | 1460-1729 kPa (212-251 psi) | 19°C (66°F) |
Above 20% | 268-330 kPa (39-48 psi) | 1467-1729 kPa (213-251 psi) | 20°C (68°F) | |
47-49°C (116-120°F) | Below 30% | 296-358 kPa (43-52 psi) | 1646-1908 kPa (239-277 psi) | 23°C (72°F) |