Note: Drain and measure as much of the refrigerant oil as possible from the removed compressor.
Rotate the compressor shaft to assist in draining the compressor.
This measurement will be used during installation of the replacement compressor.
Note: The refrigerant oil in the A/C system must be balanced during compressor replacement.
If the amount of refrigerant oil drained and recorded from the removed compressor is:
• | Less than 74 ml (2.5 oz) |
• | Leave the 74 ml (2.5 oz) in the replacement compressor. |
• | More than 74 ml (2.5 oz) |
• | Add to the compressor the difference between the 74 ml (2.5 oz) and the amount drained. |