GM Service Manual Online
For 1990-2009 cars only

Noise Diagnosis for Buick Park Avenue 1998

Condition

Possible Cause

Correction

Blower Motor Noise

  1. Foreign material is on the fan.
  2. The fan blades are broken or missing .
  3. The blower motor has internal damage.
  1. Remove the material. Reuse the blower motor if possible.
  2. Replace the motor and fan assembly.
  3. Replace the motor and fan assembly.

A/C Compressor Noise

  1. The compressor mounting bracket fasteners are not torqued to specifications
  2. The compressor mounting fasteners are not torqued to specifications.
  3. The A/C compressor pulley bearing is faulty.
  4. The belt slips.
  1. Inspect the compressor bracket to engine torque.
  2. Inspect the compressor to bracket torque.
  3. Replace the A/C compressor pulley and bearing.
  4. Inspect the belt tensioner, the idler pulley and/or the belt.

A/C Refrigerant Lines/Hoses Noise

  1. The lines or hoses are grounded.
  2. The lines or hoses rub on the other components.
  1. Reposition the A/C lines or hoses.
  2. Reposition and secure the lines and hoses.

HVAC Module Noise

  1. Foreign material is in the A/C module.
  2. The A/C module is not torqued to specifications.
  3. The actuator door is damaged.
  1. Remove the material from the case.
  2. Torque the A/C module to specifications.
  3. Repair or replace the door(s).