Step | Action | Value(s) | Yes | No |
|---|---|---|---|---|
1 |
Refer to Measuring Voltage in Wiring Systems. Does the voltage measure near the specified value? | 5 V | Go to Step 5 | Go to Step 2 |
2 |
Leave the battery and ground connected to the blower control module. Refer to Measuring Voltage in Wiring Systems. Does the voltage measure near the specified value? | 5 V | Go to Step 3 | Go to Step 6 |
3 | Inspect the HVAC programmer blower control output circuit for a short to ground. Refer to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | System OK | Go to Step 4 |
4 | Replace the HVAC control assembly. Refer to Programmer Replacement . Did you complete the repair? | -- | System OK | -- |
5 |
Refer to Testing for Continuity in Wiring Systems. Does the resistance measure less than the specified value? | 20k ohms | Go to Step 6 | Go to Step 7 |
6 | Replace the blower control module. Refer to Blower Motor Control Module Replacement . Is the repair complete? | -- | System OK | -- |
7 | Replace the blower motor. Refer to Blower Motor and Fan Replacement . Is the repair complete? | -- | System OK | -- |