Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Exterior Lights System Check? | -- | Go to Step 2 | |
2 |
Is the voltage within the specified range? | 10-15V | Go to Step 5 | Go to Step 3 |
3 | Inspect CKT 351 (BLK/WHT) between C202 and S203 for an open. Refer to Testing for Continuity in Wiring Systems. Is CKT 351 OK? | -- | Go to Step 4 | Go to Step 7 |
4 | Replace the turn signal/hazard switch. Is the repair complete? | -- | -- | |
5 | Inspect CKT 111 (WHT) for an open. Refer to Testing for Continuity in Wiring Systems. Is CKT 111 OK? | -- | Go to Step 6 | Go to Step 7 |
6 | Replace the turn signal flasher. Refer to Hazard and Turn Signal Flasher Replacement . Is the repair complete? | -- | -- | |
7 | Repair the faulty wiring. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |