Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Does the volt indicator illuminate for five seconds during bulb check? | -- | Go to Step 3 | Go to Step 4 |
3 |
Is the volt lamp commanded On? | -- | Go to Step 4 | System OK |
4 | Inspect for a faulty volt indicator bulb. Refer to Instrument Cluster Bulb Replacement . Did you find and correct the condition? | -- | Go to Step 6 | Go to Step 5 |
5 | Replace the instrument panel cluster. Refer to Instrument Cluster Replacement . Did you complete the replacement? | -- | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |