Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Lighting System Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Does the Perimeter Lamp Output parameter indicate OFF? | -- | Go to Step 3 | Go to Step 6 |
3 |
Did the backup lamps turn OFF? | -- | Go to Step 4 | Go to Step 8 |
4 |
Does the test lamp illuminate? | -- | Go to Step 5 | Go to Step 9 |
5 | Test for a short to ground in the Perim LP relay control circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 6 |
6 | Inspect for poor connections at the RFA module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 7 |
7 | Replace the remote function actuator (RFA) module. Refer to RFA Module Replacement in Keyless Entry. Did you complete the replacement? | -- | Go to Step 11 | -- |
8 | Repair the short to power in the backup lamp power circuit. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 11 | -- |
9 | Inspect for poor connections at the backup lamp relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 10 |
10 | Replace the Perim LP relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the replacement? | -- | Go to Step 11 | -- |
11 | Operate the system in order to verify the repair. Did you find and correct the condition? | -- | System OK | Go to Step 2 |