Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Lighting System Diagnostic System Check ? | -- | Go to Step 2 | |
2 | Test the DIM enable circuit for an open, high resistance or a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 5 | Go to Step 3 |
3 | Inspect for poor connections at the lighting control module (LCM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 5 | Go to Step 4 |
4 | Replace the LCM. Refer to Lamp Control Module Replacement . Did you complete the replacement? | -- | Go to Step 5 | -- |
5 | Operate the system in order to verify the repair. Did you find and correct the condition? | -- | System OK | Go to Step 2 |