The retained accessory power (RAP) system allows the following
components to operate for approximately 10 minutes after the ignition
switch is turned off:
• | The sunroof (if equipped) |
• | The cell phone (if equipped) |
When the ignition switch is turned to the ACCY or the RUN position,
voltage is applied from the IP fuse block WSW/RFA fuse to the remote function
actuator (RFA) module. When the RFA module RAP relay control output grounds
the RAP relay, the RAP relay energizes and supplies power to the RDO/PH
fuse and the SUNROOF fuse (if equipped).
When the ignition switch is turned to the OFF position, the voltage
from the IP fuse block WSW/RFA fuse to the RFA module is removed. The RFA
module continues to ground the RAP relay control output until either 10 minutes
pass or any passenger compartment door opens. The RFA module receives
a passenger compartment door status from the drivers door module (DDM) through
the class 2 serial data line. If either event occurs, power is removed from
the rear fuse block RDO/PH fuse and the rear fuse block SUNROOF fuse (if
equipped).