The LF/driver inflatable restraint side impact inflator module deployment loop is a 2 wire circuit. When you first turn ON the ignition, the inflatable restraint sensing and diagnostic module (SDM) performs tests to diagnose critical malfunctions within the SDM. Then the SDM performs the following continuous diagnostic tests on the deployment loops:
• | Deployment loop voltage out of range test |
• | Deployment loop resistance measurement test |
If the voltage out of range test detects a short to voltage condition, the resistance measurement test for that deployment loop will not be performed.
• | Ignition 1 voltage is within the normal operating voltage range. |
• | LF side deployment loop is not open. |
• | LF side deployment loop is not shorted to voltage. |
• | LF side deployment loop is not shorted to ground. |
LF side deployment loop resistance is less than 1.3 ohms for 500 milliseconds.
The SDM commands ON the AIR BAG warning lamp via Class 2 serial data.
• | The resistance of the LF side deployment loop is at least 1.3 ohms or more for 500 milliseconds. |
• | You can issue a CLEAR CODES command. |
• | A history DTC will clear once 255 malfunction free ignition cycles have occurred. |
The following can cause an intermittent condition:
• | A short between the LF side high and the LF side low circuits. |
• | A malfunctioning shorting bar on the inflatable restraint side impact inflator module 2-way harness connector. |
If any of the above conditions are found refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
The number(s) below refer to the step number(s) on the diagnostic table.
This step checks the LF/driver side air bag in-line connector for physical damage.
This step tests for a malfunctioning LF side air bag module (inflatable restraint side impact module).
This step determines if there is a short between LF side high and low deployment circuits or if there is a malfunctioning SDM.
Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Diagnostic System Check? | -- | ||||||||
Does the connector exhibit any signs of corrosion, terminal damage, or poor connections? | -- | |||||||||
3 |
Did you complete the replacement? | -- | -- | |||||||
4 |
Does the scan tool indicate that this DTC is current? | -- | Go to Diagnostic Aids | |||||||
Does the scan tool indicate that this DTC is current? | -- | |||||||||
6 |
Did you complete the replacement? | -- | -- | |||||||
Does the resistance measure less than the specified value? | OL | |||||||||
8 | Locate and repair the short between high and low deployment circuits. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |||||||
9 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Did you complete the replacement? | -- | -- | |||||||
10 |
Did you complete the action? | -- | -- |