Step | Action | Value(s) | Yes | No | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: The temperature cannot be adjusted, or the cooling is insufficient during A/C operation. | ||||||||||||||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |||||||||||||||||||||
2 |
Important:: In order to execute the HVAC Recalibration command, the scan tool disrupts keep alive memory (KAM) causing DTC B1652 (Loss of KAM) to be set as history.
Does the scan tool display DTC B1340, B1341, B1343, or B1344? | -- | Go to Step 3 | |||||||||||||||||||||
3 | Place the blower motor switch in each speed position. Does the blower motor operate in any of the speed positions? | -- | Go to Step 4 | Go to Blower Motor Inoperative | ||||||||||||||||||||
4 | Does the blower motor operate in each speed position? | -- | Go to Step 5 | Go to Blower Motor Malfunction | ||||||||||||||||||||
5 |
Important:: Ambient air temperature must be above 5°C (41°F).
Does the A/C compressor operate? | -- | Go to Step 6 | |||||||||||||||||||||
6 | Perform the A/C system performance test. Refer to Air Conditioning (A/C) System Performance Test in Heating, Ventilating, and Air Conditioning. Did you find and correct the condition? | -- | Go to Step 34 | Go to Step 7 | ||||||||||||||||||||
7 |
Does the scan tool indicate that the Left Temp Dr. Commanded parameter change? | -- | Go to Step 8 | Go to Step 30 | ||||||||||||||||||||
8 |
Does left air temperature actuator drive shaft rotate? | -- | Go to Step 10 | Go to Step 9 | ||||||||||||||||||||
9 |
Does the scan tool indicate that the Left Air Temp Dr. Actual parameter is less the specified value? | 10 Counts | Go to Step 10 | Go to Step 23 | ||||||||||||||||||||
10 |
Does the scan tool indicate that the Right Temp Dr. Commanded parameter change? | -- | Go to Step 11 | Go to Step 30 | ||||||||||||||||||||
11 |
Does right air temperature actuator drive shaft rotate? | -- | Go to Step 14 | Go to Step 12 | ||||||||||||||||||||
12 |
Does the scan tool indicate that the Right Air Temp Dr. Actual parameter is less the specified value? | 10 Counts | Go to Step 13 | Go to Step 25 | ||||||||||||||||||||
13 | Inspect the suspect air temperature door and the suspect air temperature actuator for the following conditions:
Did you find and correct the condition? | -- | Go to Step 34 | Go to Step 27 | ||||||||||||||||||||
14 | Inspect each of the air temperature sensors for proper installation. Refer to the following procedures: Did you find and correct the condition? | -- | Go to Step 34 | Go to Step 15 | ||||||||||||||||||||
15 |
Does the paper stay in place? | -- | Go to Step 16 | Go to Step 20 | ||||||||||||||||||||
16 |
Does the scan tool indicate that the data parameters are greater than the specified value? | 230 Counts | Go to Step 17 | Go to Step 29 | ||||||||||||||||||||
17 |
Do the counts change similarly and correspond to the proper sunload sensor? | -- | Go to Step 18 | Go to Step 29 | ||||||||||||||||||||
18 |
Do the scan tool temperatures differ from the thermometer temperatures by less than the specified value? | 3°C (5°F) | Go to Step 19 | Go to Step 21 | ||||||||||||||||||||
19 | Does the customer need to change the set temperature frequently to maintain comfort? | -- | Go to Air Conditioning (A/C) System Does Not Maintain Set Temperature | System OK | ||||||||||||||||||||
20 | Inspect for a blocked or disconnected aspiration hose. Did you find and correct the condition? | -- | Go to Step 34 | -- | ||||||||||||||||||||
21 | Inspect for poor connections at the harness connector of the suspect temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 34 | Go to Step 22 | ||||||||||||||||||||
22 | Test the suspect temperature sensor resistance. Refer to Sensor Resistance Table . Does the resistance measure near the Sensor Resistance Table value? | -- | Go to Step 30 | Go to Step 31 | ||||||||||||||||||||
23 | Test the door position signal circuit of the left air temperature actuator for an open, a high resistance, or a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 34 | Go to Step 24 | ||||||||||||||||||||
24 | Test the low reference circuit of the left air temperature actuator for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 34 | Go to Step 30 | ||||||||||||||||||||
25 | Test the door position signal circuit of the right air temperature actuator for an open, a high resistance, or a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 34 | Go to Step 26 | ||||||||||||||||||||
26 | Test the low reference circuit of the right air temperature actuator for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 34 | Go to Step 30 | ||||||||||||||||||||
27 | Inspect for poor connections at the harness connector or at the suspect air temperature actuator. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 34 | Go to Step 28 | ||||||||||||||||||||
28 | Replace the suspect air temperature actuator. Refer to Air Temperature Actuator Replacement - Right Side or Air Temperature Actuator Replacement - Left Side . Did you complete the replacement? | -- | Go to Step 34 | -- | ||||||||||||||||||||
29 | Inspect for poor connections at the harness connector of the suspect sunload sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 34 | Go to Step 32 | ||||||||||||||||||||
30 | Inspect for poor connections at the harness connector of the instrument panel integration module (IPM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 34 | Go to Step 33 | ||||||||||||||||||||
31 | Replace the suspect temperature sensor. Refer to the following procedures: Did you complete the replacement? | -- | Go to Step 34 | -- | ||||||||||||||||||||
32 | Replace the suspect sunload sensor. Refer to Sun Load Sensor Replacement - Left Side or Sun Load Sensor Replacement - Right Side . Did you complete the replacement? | -- | Go to Step 34 | -- | ||||||||||||||||||||
33 |
Important:: Perform the recalibration procedure for the instrument panel integration module (IPM). Replace the IPM. Refer to Instrument Panel Module Replacement in Body Control System. Did you complete the replacement? | -- | Go to Step 34 | -- | ||||||||||||||||||||
34 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |