Tools Required
J 5403 Snap Ring
Pliers
- Coat the O-rings with
525 viscosity refrigeration oil.
- Using thumb pressure, push the O-rings in place.
- Install the valve into the case.
Important: Ensure that the retaining ring is properly seated in the ring groove.
- Using the J 5403
,
install the valve retaining ring (5) with the high point of the curved
sides against the valve housing.
- Perform a leak test. Refer to
Compressor Leak Testing
.