DTC B1657 indicates that the option bit portion of the instrument panel cluster (IPC) electrically erasable programmable read only memory (EEPROM) has an unrecoverable error. The option bit portion of the instrument cluster EEPROM stores the manufacturing information.
DTC B1657 sets when the IPC detects an error in the option bit portion of the EEPROM during a diagnostic system self-test.
The module must be active/awake.
When DTC B1657 sets, the following actions may occur:
• | The IPC display does not operate. |
• | The IPC illuminates the MIL. |
• | A current DTC clears when the malfunction is no longer present. |
• | A history DTC clears when the module ignition cycle counter reaches the reset threshold, without a repeat of the malfunction. |
• | This DTC may be stored as a history DTC with out affecting the operation of the module. If stored only as a history DTC and not retrieved as a current DTC, do not replace the module. |
• | If this DTC is retrieved as both a current and history DTC, replace the module. |
Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Diagnostic System Check for the system exhibiting the symptom? | Go to Step 2 | Go to Control Module References for the applicable Diagnostic System Check |
2 |
Is the DTC retrieved as a current DTC? | Go to Step 3 | Go to Diagnostic Aids |
3 |
Important: Perform the programming or setup procedure for the module if required. Replace the control module setting the DTC as current. Refer to Control Module References . Did you complete the replacement? | Go to Step 4 | -- |
4 |
Does the DTC reset? | Go to Step 2 | System OK |