Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Starting and Charging Schematics Connector End View Reference: Engine Electrical Connector End Views | |||
1 | Did you perform the Engine Electrical Diagnostic System Check? | Go to Step 2 | |
2 | Turn the ignition to the START position. Did the starter solenoid click? | Go to Step 3 | |
3 | Inspect the engine and belt drive system for mechanical binding such as a seized engine or seized generator. Does the engine move freely? | Go to Step 4 | Go to Engine Will Not Crank - Crankshaft Will Not Rotate in Engine Mechanical - 3.8L |
4 | Test the battery positive cable between the battery and the starter solenoid for high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 5 |
5 | Test the ground circuit between the battery and the starter motor for a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 6 |
6 | Inspect for poor connections at the starter. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 7 |
7 | Replace the starter. Refer to Starter Motor Replacement Did you complete the replacement? | Go to Step 8 | -- |
8 | Operate the system for which the symptom occurred. Did you correct the condition? | System OK | Go to Step 2 |