Removal Procedure
- Remove the right side
sound insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages and Console.
- Disconnect the electrical connector from the blower motor.
- Remove the cooling hose from the blower motor.
- Remove the screws that attach the blower motor.
- Remove the blower motor from the HVAC module.
Installation Procedure
- Install the blower motor to the HVAC module assembly.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the blower motor screws.
Tighten
Tighten the screws to 1.4 N·m (12 lb in).
- Install the cooling hose to the blower motor.
- Connect the electrical connector to the blower motor.
- Install the right side sound insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument
Panel, Gages and Console.